Literature DB >> 7930065

Correction of ultrasonic wavefront distortion using backpropagation and a reference waveform method for time-shift compensation.

D L Liu1, R C Waag.   

Abstract

A model is introduced to describe ultrasonic pulse amplitude and shape distortion as well as arrival time fluctuation produced by propagation through specimens of human abdominal wall. In the model, amplitude and shape distortion develops as the wavefront propagates in a uniform medium after passing through a phase screen that only causes time shifts. This distortion is compensated by a backpropagation of the wavefront using the angular spectrum method. The compensation employed waveforms emitted by a pointlike source and measured after propagation through the tissue. The waveforms were first corrected for geometric path and then were backpropagated over a sequence of increasing distances. At each distance, a waveform similarity factor was calculated to find the backpropagation distance at which the waveforms were most similar. A new method was devised to estimate pulse arrival time for geometric correction as well as to perform time-shift compensation. The method adaptively derives a reference waveform that is then cross correlated with all the waveforms in the aperture to obtain a surface of arrival times. The surface was smoothed iteratively to remove outlying points due to waveform distortion. The mean (+/- s.d.) of the waveform similarity factor for 14 specimens was found to be 0.938 (+/- 0.025) initially. After backpropagation of waveforms to the distance of maximum waveform similarity for each specimen, the waveform similarity factor improved to 0.967 (+/- 0.015). The corresponding energy level fluctuation in the wavefront was 4.2 (+/- 0.4) dB initially and became 3.3 (+/- 0.3) dB after backpropagation. For wavefronts focused at 180 mm, the -30 dB mean (+/- s.d.) effective radius of the focus was 4.2 (+/- 1.2) mm with time-shift compensation in the aperture and became 2.5 (+/- 0.5) mm with backpropagation followed by time-shift compensation. These results indicate that a phase screen placed some distance away from the aperture is an improved model for the description of wavefront distortion produced by human abdominal wall and that wavefront backpropagation followed by time-shift estimation and compensation is an effective method to compensate for such distortion.

Entities:  

Mesh:

Year:  1994        PMID: 7930065     DOI: 10.1121/1.410304

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  23 in total

1.  Shape-based ultrasound tomography using a Born model with application to high intensity focused ultrasound therapy.

Authors:  Başak Ulker Karbeyaz; Eric L Miller; Robin O Cleveland
Journal:  J Acoust Soc Am       Date:  2008-05       Impact factor: 1.840

2.  Harmonic source wavefront aberration correction for ultrasound imaging.

Authors:  Scott W Dianis; Olaf T von Ramm
Journal:  J Acoust Soc Am       Date:  2011-01       Impact factor: 1.840

3.  Ultrasonic multipath and beamforming clutter reduction: a chirp model approach.

Authors:  Brett Byram; Marko Jakovljevic
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-03       Impact factor: 2.725

4.  Angular coherence in ultrasound imaging: Theory and applications.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2017-03       Impact factor: 1.840

Review 5.  Production of acoustic radiation force using ultrasound: methods and applications.

Authors:  Matthew W Urban
Journal:  Expert Rev Med Devices       Date:  2018-10-31       Impact factor: 3.166

6.  Soft-Tissue Aberration Correction for Histotripsy.

Authors:  Jonathan J Macoskey; Timothy L Hall; Jonathan R Sukovich; Sang Won Choi; Kimberly Ives; Eric Johnsen; Charles A Cain; Zhen Xu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

7.  Comparison of 3-D multi-lag cross- correlation and speckle brightness aberration correction algorithms on static and moving targets.

Authors:  Nikolas M Ivancevich; Jeremy J Dahl; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-10       Impact factor: 2.725

8.  Robust finite impulse response beamforming applied to medical ultrasound.

Authors:  Drake A Guenther; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-06       Impact factor: 2.725

9.  In vivo application of short-lag spatial coherence imaging in human liver.

Authors:  Marko Jakovljevic; Gregg E Trahey; Rendon C Nelson; Jeremy J Dahl
Journal:  Ultrasound Med Biol       Date:  2013-01-21       Impact factor: 2.998

10.  Synergistic enhancements of ultrasound image contrast with a combination of phase aberration correction and dual apodization with cross-correlation.

Authors:  Junseob Shin; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.