Semiportable electrochemical instrument for determining carbon monoxide in breath.

H J Vreman1, D K Stevenson, W Oh, A A Fanaroff, L L Wright, J A Lemons, E Wright, S Shankaran, J E Tyson, S B Korones.   

Abstract

Measurements of carbon monoxide (CO) in breath can be used for the diagnosis of hemolytic disease. A small, semiportable, easy-to-operate CO instrument was developed at Stanford University and tested at 12 Neonatal Research Network Centers of the National Institute of Child Health and Human Development. A syringe pump delivers 7.7 mL of sample per minute through an activate carbon filter to an electrochemical (EC) sensor having a sensitivity of 0.10 +/- 0.01 V per 1 microL/L CO in air. The electronically processed sensor signal is displayed on a digital multimeter. For a typical end-tidal CO measurement, corrected for inhaled CO, three 10- to 12-mL breath and room air samples are manually or mechanically collected and analyzed. CO determination in breath samples from 108 healthy, 1-day-old infants of nonsmoking mothers compared favorably with determinations by gas chromatography (GC), 1.3 +/- 0.8 vs 1.2 +/- 0.8 (mean +/- SD), respectively, with a regression equation of EC = 0.95 GC+0.13 (r2 = 0.98). The results demonstrate that the EC-CO instrument yields results that are comparable with those obtained by the more difficult to perform GC assay.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7923774

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  7 in total

1.  Neonatal bilirubin production-conjugation imbalance: effect of glucose-6-phosphate dehydrogenase deficiency and borderline prematurity.

Authors:  M Kaplan; M Muraca; H J Vreman; C Hammerman; M T Vilei; F F Rubaltelli; D K Stevenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-03       Impact factor: 5.747

2.  Gasotransmitter Heterocellular Signaling.

Authors:  Gopi K Kolluru; Xinggui Shen; Shuai Yuan; Christopher G Kevil
Journal:  Antioxid Redox Signal       Date:  2017-04-06       Impact factor: 8.401

3.  Neonatal bilirubin production, reflected by carboxyhaemoglobin concentrations, in Down's syndrome.

Authors:  M Kaplan; H J Vreman; C Hammerman; D K Stevenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-07       Impact factor: 5.747

4.  Validation of the Natus CO-Stat End Tidal Breath Analyzer in children and adults.

Authors:  H J Vreman; R J Wong; P Harmatz; A A Fanaroff; B Berman; D K Stevenson
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

Review 5.  Carbon monoxide in exhaled breath testing and therapeutics.

Authors:  Stefan W Ryter; Augustine M K Choi
Journal:  J Breath Res       Date:  2013-02-27       Impact factor: 3.262

Review 6.  End-tidal carbon monoxide and hemolysis.

Authors:  G F Tidmarsh; R J Wong; D K Stevenson
Journal:  J Perinatol       Date:  2014-04-17       Impact factor: 2.521

7.  Metalloporphyrins - an update.

Authors:  Stephanie Schulz; Ronald J Wong; Hendrik J Vreman; David K Stevenson
Journal:  Front Pharmacol       Date:  2012-04-26       Impact factor: 5.810

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.