Drug quality screening in developing countries: establishment of an appropriate laboratory in Swaziland.

T A Kenyon1, A S Kenyon, T Sibiya.   

Abstract

A simple, low-cost, accurate thin-layer chromatography (TLC) method has been used to establish the first drug quality screening laboratory in Swaziland. For this purpose, office space at the central medical stores was first converted into a simple laboratory. Basic equipment, supplies, and materials were purchased, existing manpower was trained to perform accurately the TLC procedure, and a system was established for the qualitative/quantitative screening of selected drugs purchased by the Ministry of Health prior to their distribution to user facilities. The TLC method described can be used to set up similar low-cost, drug quality screening laboratories in other developing countries where analytical chemistry expertise is lacking, resources are scarce, and sophisticated analytical laboratories to assess drug quality are not available.

Mesh:

Substances:

Year:  1994        PMID: 7923541      PMCID: PMC2486607     

Source DB:  PubMed          Journal:  Bull World Health Organ        ISSN: 0042-9686            Impact factor:   9.408


  3 in total

1.  Debt crisis, health and health services in Africa.

Authors:  S O Alubo
Journal:  Soc Sci Med       Date:  1990       Impact factor: 4.634

2.  Combating counterfeit drugs.

Authors:  T Land
Journal:  Nature       Date:  1992-01-16       Impact factor: 49.962

3.  A simple, inexpensive thin-layer chromatography method for the analysis of theophylline tablets.

Authors:  P E Flinn; Y H Juhl; T P Layloff
Journal:  Bull World Health Organ       Date:  1989       Impact factor: 9.408

  3 in total
  3 in total

1.  The quality of drugs in private pharmacies in Lao PDR: a repeat study in 1997 and 1999.

Authors:  Lamphone Syhakhang; Cecilia Stålsby Lundborg; Björn Lindgren; Göran Tomson
Journal:  Pharm World Sci       Date:  2004-12

2.  Rapid screening of marketed paracetamol tablets: use of thin-layer chromatography and a semiquantitative spot test.

Authors:  J Roy; P Saha; S Sultana; A S Kenyon
Journal:  Bull World Health Organ       Date:  1997       Impact factor: 9.408

Review 3.  Substandard drugs: a potential crisis for public health.

Authors:  Atholl Johnston; David W Holt
Journal:  Br J Clin Pharmacol       Date:  2014-08       Impact factor: 4.335

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.