Literature DB >> 7923046

An accurate and ergonomic method of registration for image-guided neurosurgery.

J M Henderson1, K R Smith, R D Bucholz.   

Abstract

We have developed a system for accurately and conveniently achieving surgical registration for image-guided neurosurgery, based on alignment and matching of patient forehead contours. The system consists of a contour digitizer that is used in the operating room to acquire patient contours, editing software for extracting contours from patient image data sets, and a contour-match algorithm for aligning the two contours and performing data set registration. Initial tests of the individual portions of the system have found each to be robust; we are in the process of refining the design of the optical digitizer in order to further automate the procedure as well as provide increased accuracy.

Entities:  

Mesh:

Year:  1994        PMID: 7923046     DOI: 10.1016/0895-6111(94)90051-5

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  6 in total

Review 1.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

2.  Design and evaluation of an optically-tracked single-CCD laser range scanner.

Authors:  Thomas S Pheiffer; Amber L Simpson; Brian Lennon; Reid C Thompson; Michael I Miga
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

3.  Intraoperative fiducial-less patient registration using volumetric 3D ultrasound: a prospective series of 32 neurosurgical cases.

Authors:  Xiaoyao Fan; David W Roberts; Songbai Ji; Alex Hartov; Keith D Paulsen
Journal:  J Neurosurg       Date:  2015-07-03       Impact factor: 5.115

Review 4.  Neuronavigation and surgery of intracerebral tumours.

Authors:  P W A Willems; J W Berkelbach van der Sprenkel; C A F Tulleken; M A Viergever; M J B Taphoorn
Journal:  J Neurol       Date:  2006-09-20       Impact factor: 4.849

5.  Comparison of registration accuracy of skin- and bone-implanted fiducials for frameless stereotaxis of the brain: a prospective study.

Authors:  Mario Ammirati; Jeffrey D Gross; Giuseppe Ammirati; Sharon Dugan
Journal:  Skull Base       Date:  2002-08

6.  Challenges in image-guided therapy system design.

Authors:  Simon Dimaio; Tina Kapur; Kevin Cleary; Stephen Aylward; Peter Kazanzides; Kirby Vosburgh; Randy Ellis; James Duncan; Keyvan Farahani; Heinz Lemke; Terry Peters; William Bill Lorensen; David Gobbi; John Haller; Laurence Larry Clarke; Stephen Pizer; Russell Taylor; Robert Galloway; Gabor Fichtinger; Nobuhiko Hata; Kimberly Lawson; Clare Tempany; Ron Kikinis; Ferenc Jolesz
Journal:  Neuroimage       Date:  2007-04-24       Impact factor: 6.556

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.