Literature DB >> 7907897

Angle correction in transcranial Doppler sonography.

B M Eicke1, C H Tegeler, G Dalley, L G Myers.   

Abstract

Since the introduction of transcranial Doppler sonography in the early 1980s, flow velocity estimates have assumed a 0- to 30-degree angle of insonation. Based on limited radiological and anatomical studies, such as assumption appeared justified, and seemed to confer only minimal potential for error due to the cosine function in the Doppler formula. The introduction of transcranial color duplex sonography allows the direct evaluation of this assumption and the effect on flow velocities. Fifteen healthy volunteers were studied bilaterally using a unilateral transtemporal approach from the right. Velocity measurements were taken from the middle, anterior, and posterior cerebral arteries. Flow velocities were obtained with and without angle correction (0 degree). After completion of the color duplex study, velocities were obtained with a conventional, "blind" Doppler transducer at corresponding depths. For all insonated vessels the average angle of insonation was around 30 degrees. However, there was a wide variability of individual angles of insonation (0-70 degrees) in specific vessels. In 74.5% of all vessels, the angle-corrected flow velocity did not exceed the uncorrected velocity by more than 25%. In 14.5% the angle-corrected velocity was 25 to 50% higher and in 10.8% it was more than 50% higher as compared to the uncorrected velocity. Thus, the angle of insonation was unpredictable and often higher than originally expected. Angle-corrected velocities were higher than uncorrected values, and were more than 25% higher in about one-fourth of the vessels studied. Understanding of the clinical importance of such differences requires further study.

Mesh:

Year:  1994        PMID: 7907897     DOI: 10.1111/jon19944129

Source DB:  PubMed          Journal:  J Neuroimaging        ISSN: 1051-2284            Impact factor:   2.486


  3 in total

1.  Noninvasive Intracranial Pressure Assessment in Acute Liver Failure.

Authors:  Venkatakrishna Rajajee; Craig A Williamson; Robert J Fontana; Anthony J Courey; Parag G Patil
Journal:  Neurocrit Care       Date:  2018-10       Impact factor: 3.210

2.  Importance of angle correction in the measurement of blood flow velocity with transcranial Doppler sonography.

Authors:  J Krejza; Z Mariak; V L Babikian
Journal:  AJNR Am J Neuroradiol       Date:  2001-10       Impact factor: 3.825

3.  TCD Cerebral Hemodynamic Changes during Moderate-Intensity Exercise in Older Adults.

Authors:  Mohammed R Alwatban; Yumei Liu; Sophy J Perdomo; Jaimie L Ward; Eric D Vidoni; Jeffrey M Burns; Sandra A Billinger
Journal:  J Neuroimaging       Date:  2019-11-21       Impact factor: 2.486

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.