Literature DB >> 7896639

Evaluation of the needle technique for producing an arteriovenous fistula.

M Huang1, M H LeBlanc, R L Hester.   

Abstract

The purpose of the present study were to evaluate the needle technique of creating an arteriovenous (a-v) fistula and to quantitatively determine the hemodynamic responses in rats with three different fistula sizes. The fistula was made in male Sprague-Dawley rats between the aorta and vena cava below the renal arteries by using 20-, 18-, and 16-gauge angiocath needles. Five weeks after a sham operation or creation of an a-v fistula, mean arterial blood pressure (MAP), right atrial pressure, shunt flow, cardiac index, systemic flow, individual organ flows, and heart weight were quantitatively determined. All flow measurements were made using radioactive microspheres. The flow to the lungs was used as a measure of shunt flow. The shunt flow in the 20-, 18-, and 16-gauge fistula animals was significantly increased from a value of 2 +/- 1% (SE) to 50.0 +/- 0.1, 78 +/- 3, and 76 +/- 3% of total cardiac output, respectively. Average cardiac index in the 20-, 18-, and 16-gauge fistula animals increased by 105, 270, and 250%, respectively, compared with control. Right atrial pressure and heart weight were increased in proportion to the size of the fistula. MAP in the control and 20-, 18-, and 16-gauge fistula animals was 122 +/- 5, 126 +/- 3, 118 +/- 3, and 111 +/- 4 mmHg, respectively. There were no significant differences in MAP or systemic flow among any of these groups. The calculated total peripheral resistance in all fistula groups was significantly decreased compared with control.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7896639     DOI: 10.1152/jappl.1994.77.6.2907

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

Review 1.  Surgical and physiological challenges in the development of left and right heart failure in rat models.

Authors:  Michael G Katz; Anthony S Fargnoli; Sarah M Gubara; Elena Chepurko; Charles R Bridges; Roger J Hajjar
Journal:  Heart Fail Rev       Date:  2019-09       Impact factor: 4.214

Review 2.  Aortocaval fistula in rat: a unique model of volume-overload congestive heart failure and cardiac hypertrophy.

Authors:  Zaid Abassi; Ilia Goltsman; Tony Karram; Joseph Winaver; Aaron Hoffman
Journal:  J Biomed Biotechnol       Date:  2011-01-11

3.  Impact of aortocaval shunt flow on cardiac and renal function in unilateral nephrectomized rats.

Authors:  Jie Wu; Zhong Cheng; Mingjing Zhang; Pengfei Zhu; Ye Gu
Journal:  Sci Rep       Date:  2016-06-09       Impact factor: 4.379

4.  A modified approach to induce predictable congestive heart failure by volume overload in rats.

Authors:  Sascha Treskatsch; Aarne Feldheiser; Adrian T Rosin; Marco Sifringer; Helmut Habazettl; Shaaban A Mousa; Mehdi Shakibaei; Michael Schäfer; Claudia D Spies
Journal:  PLoS One       Date:  2014-01-31       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.