Flow patterns and endothelial cell morphology in a simplified model of an artificial ventricle.

M M Samet1, P I Lelkes.   

Abstract

The aim of this study was to delineate the flow patterns in a non-unidirectional flow field inside a ventricle-shaped cell culture chamber, and examine the resulting morphology and integrity of the endothelium in select regions of the monolayer. The chamber was perfused by pulsatile flow, and the coherent motion of the fluid was studied using flow visualization aided by image analysis. Four distinct flow patterns were discerned and examined: central jet, flow impingement, flow separation, and recirculating eddies. The influence of these patterns on endothelial cell morphology was assessed after 20 h of exposure to flow. There were no signs of damage to the endothelium in the jet region nor was there evidence of cell alignment with the flow. Yet, there were changes in cell morphology and cytoskeletal architecture as compared to control. By contrast, within the eddies where the flow was highly disturbed, there was apparent damage to the endothelium. Thus, exposure of cells to random velocity fluctuations in regions of quasi-static flow compromises the integrity of the monolayer. Identification of such sites and acquisition of the knowledge necessary to protect the cells from denudation will be valuable for the endothelialization efforts of cardiac prostheses.

Mesh:

Year:  1993        PMID: 7895248     DOI: 10.1007/BF02796510

Source DB:  PubMed          Journal:  Cell Biophys        ISSN: 0163-4992


  25 in total

1.  Endothelialization of vascular prosthetic surfaces after seeding or sodding with human microvascular endothelial cells.

Authors:  M A Rupnick; F A Hubbard; K Pratt; B E Jarrell; S K Williams
Journal:  J Vasc Surg       Date:  1989-06       Impact factor: 4.268

2.  Haemodynamic shear stress activates a K+ current in vascular endothelial cells.

Authors:  S P Olesen; D E Clapham; P F Davies
Journal:  Nature       Date:  1988-01-14       Impact factor: 49.962

3.  Vascular endothelium: nature's blood-compatible container.

Authors:  M A Gimbrone
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

4.  Hot-film wall shear probe measurements inside a ventricular assist device.

Authors:  J T Baldwin; J M Tarbell; S Deutsch; D B Geselowitz; G Rosenberg
Journal:  J Biomech Eng       Date:  1988-11       Impact factor: 2.097

5.  Pattern of blood flow within the heart: a stable system.

Authors:  D E Taylor; J D Wade
Journal:  Cardiovasc Res       Date:  1973-01       Impact factor: 10.787

6.  Laser Doppler anemometer studies in unsteady ventricular flows.

Authors:  W M Phillips; S S Furkay; W S Pierce
Journal:  Trans Am Soc Artif Intern Organs       Date:  1979

7.  The dynamic response of vascular endothelial cells to fluid shear stress.

Authors:  C F Dewey; S R Bussolari; M A Gimbrone; P F Davies
Journal:  J Biomech Eng       Date:  1981-08       Impact factor: 2.097

8.  Endothelial nuclear patterns in the canine arterial tree with particular reference to hemodynamic events.

Authors:  J T Flaherty; J E Pierce; V J Ferrans; D J Patel; W K Tucker; D L Fry
Journal:  Circ Res       Date:  1972-01       Impact factor: 17.367

9.  Growth properties of cultured human endothelial cells on differently coated artificial heart materials.

Authors:  P Zilla; R Fasol; M Grimm; T Fischlein; T Eberl; P Preiss; O Krupicka; U von Oppell; M Deutsch
Journal:  J Thorac Cardiovasc Surg       Date:  1991-04       Impact factor: 5.209

10.  Adaptive regulation of wall shear stress to flow change in the canine carotid artery.

Authors:  A Kamiya; T Togawa
Journal:  Am J Physiol       Date:  1980-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.