Literature DB >> 7894670

Sensitive method for the assay of sertindole in plasma by high-performance liquid chromatography and fluorimetric detection.

T B Tzeng1, G Stamm, S Y Chu.   

Abstract

A simple and highly sensitive normal-phase HPLC method is described for determining sertindole concentrations in human plasma using fluorimetric detection. A short C8 column was used to extract sertindole and the internal standard from plasma; the column was rinsed with acetonitrile, and the analytes were recovered by elution with methanol. This uncommon selectivity between the two solvents allowed clean extraction and near- quantitative recovery of the analytes (> 89%). Separation was done on a 5-microns silica-gel column and detection was performed by fluorimetry, with emission at 340 nm and excitation at 260 nm. The detection and lower quantifiable limits were 0.01 and 0.025 ng/ml, respectively, with no interference from plasma or potential metabolites.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7894670     DOI: 10.1016/0378-4347(94)00356-4

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Appl        ISSN: 1572-6495


  2 in total

Review 1.  The Black Book of Psychotropic Dosing and Monitoring.

Authors:  Alan F Schatzberg; DeBattista Charles
Journal:  Psychopharmacol Bull       Date:  2018-01-15

2.  Identification and synthesis of impurities formed during sertindole preparation.

Authors:  I V Sunil Kumar; G S R Anjaneyulu; V Hima Bindu
Journal:  Beilstein J Org Chem       Date:  2011-01-07       Impact factor: 2.883