Literature DB >> 7882813

Reliability and validity of cardiovascular and vasomotor autonomic function tests.

M S Hartwig1, S S Cardoso, D K Hathaway, A O Gaber.   

Abstract

OBJECTIVE: To determine the reliability and validity of autonomic function tests (AFTs) as clinical tools for diagnosing diabetic autonomic dysfunction. RESEARCH DESIGN AND METHODS: Twenty-one healthy control subjects and 21 insulin-dependent diabetes mellitus (IDDM) patients (11 with no symptomatology and 10 with symptomatic diabetic autonomic neuropathy [DAN]) were matched for age, and administered three standard cardiovascular tests and two new vasomotor tests of autonomic function. Each of the cardiovascular tests (change in heart rate [delta bpm], Valsalva ratio [VR], change in systolic blood pressure [delta sBP]) and vasomotor tests (total pulse amplitude [TPA] and percent vasoconstriction [%VC]) were repeated within 1 week. Infrared photoplethysmography measured sympathetic-mediated vasomotor function. Reliability was determined by intraclass correlation coefficients. Validity was determined by analysis of variance procedures to test for differences between known groups and by computing sensitivity, specificity, and positive and negative predictive values.
RESULTS: All AFTs were reliable, with %VC having highest reproducibility (r = 0.90). AFT scores were not different from time 1 to time 2. After controlling for age, two cardiovascular tests had significantly different values for control subjects and asymptomatic diabetic patients. AFTs, except delta sBP, were significantly different between symptomatic diabetic patients and asymptomatic diabetic patients after controlling for age and duration of disease simultaneously. Sensitivity, specificity, and predictive values for %VC were comparable to the values for delta bpm and VR. TPA indexes were lower but clinically acceptable.
CONCLUSIONS: AFTs were found to be reliable and valid tests for detecting DAN. TPA and %VC are important because they measure an aspect of sympathetic function not assessed by standard cardiovascular AFTs, and they do not depend on the patient's cooperation or ability to exert effort.

Entities:  

Mesh:

Year:  1994        PMID: 7882813     DOI: 10.2337/diacare.17.12.1433

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  5 in total

1.  Reliability of orthostatic beat-to-beat blood pressure tests: implications for population and clinical studies.

Authors:  C Finucane; G M Savva; R A Kenny
Journal:  Clin Auton Res       Date:  2017-01-12       Impact factor: 4.435

2.  Serum catecholamines and dysautonomia in diabetic gastroparesis and liver cirrhosis.

Authors:  Naeem Aslam; Archana Kedar; Harsha S Nagarajarao; Kartika Reddy; Hani Rashed; Teresa Cutts; Caroline Riely; Thomas L Abell
Journal:  Am J Med Sci       Date:  2015-08       Impact factor: 2.378

3.  Reproducibility of exercise-induced modulation of cardiovascular responses to cold stress.

Authors:  H M Rashed; G Leventhal; E C Madu; R Reddy; S Cardoso
Journal:  Clin Auton Res       Date:  1997-04       Impact factor: 4.435

4.  Assessment of gastric electrical activity and autonomic function among diabetic and nondiabetic patients with symptoms of gastroesophageal reflux.

Authors:  A L Jackson; H Rashed; S Cardoso; F Wong; R Werkman; J Thompson; T L Abell
Journal:  Dig Dis Sci       Date:  2000-09       Impact factor: 3.199

5.  Cardiovascular autonomic neuropathy in people with type 2 diabetes mellitus; investigation of its association with classical cardiovascular risk factors using cardiovascular autonomic reflex tests: a cross-sectional study.

Authors:  Ahmad Osailan
Journal:  Egypt Heart J       Date:  2021-05-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.