L Dlugosz1, K Belanger, P Johnson, M B Bracken.
Abstract
Two types of dosimeters for measuring human exposure to 60 Hz magnetic fields were compared. Fifty adults wore the single-axis, wrist model AMEX (average magnetic field exposure system) and the triple axis, hip-pocket or pouch model AMEX-3D meters for 2 days. Ninety-six percent of the tests were accomplished without apparent dosimeter failure. The average root mean square magnetic flux density measurements with the AMEX-3D (mean = 0.10 microT, S.D. = 0.07, range = 0.03-0.31) were significantly higher than with the AMEX meter (mean = 0.07 microT, S.D. 0.05, range = 0.02-0.27 microT) (t test, P < 0.01). There was substantial correlation between the AMEX and the AMEX-3D measurements (Pearson's correlation coefficient = 0.65, P < 0.01) but poor concordance (Intraclass correlation coefficient = -0.25). These results suggest that there is a wide variation in exposure to extremely low frequency magnetic fields in the population. Magnetic field measurements with the AMEX-3D are nearly always higher than with the AMEX dosimeters. Caution is advised when comparing magnetic field measurements made with different types of dosimeters.Entities:
Mesh:
Year: 1994 PMID: 7880173 DOI: 10.1002/bem.2250150613
Source DB: PubMed Journal: Bioelectromagnetics ISSN: 0197-8462 Impact factor: 2.010