Design and fabrication of well confined uniform magnetic field exposure systems.

B W Wilson1, K Caputa, M A Stuchly, J D Saffer, K C Davis, C E Washam, L G Washam, G R Washam, M A Wilson.   

Abstract

Exposure systems that provide good magnetic field uniformity, minimum stray fields, and minimal heating, vibration, and hum, as well as capability for true sham exposure in which current flows in the coils, are needed to determine rigorously the biological effects of weak magnetic fields. Designs based on acrylic polymer coil support structures and twisted pair bifilary coil windings were employed to fabricate several different systems for the exposure of laboratory animals and cell cultures to magnetic fields. These systems exhibit excellent performance characteristics in terms of exposure field uniformity, stray field containment, and exposure field cancellation in the sham exposure mode. A custom-written computer program was used to determine the best arrangement for coils with regard to field uniformity in the exposure volume and stray field containment. For in vivo exposures, modules were made up of four Merritt four-coil sets, built into a single structure and positioned to form an octapole with fields directed in the horizontal plane. For in vitro applications, two different coil configurations were selected to produce the vertical fields required. A quadrupole system, comprising modules consisting of two Merritt four-coil sets arranged side by side to limit stray fields, was built as a prototype. In the second configuration, one Merritt four-coil set was positioned inside the other to form a concentric coil set. In both in vitro systems, exposure chambers were connected to remote commercial incubators in order to reduce ambient magnetic fields in the exposure volume.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7880170     DOI: 10.1002/bem.2250150610

Source DB:  PubMed          Journal:  Bioelectromagnetics        ISSN: 0197-8462            Impact factor:   2.010


  3 in total

1.  Treatment pulse application for magnetic stimulation.

Authors:  Sun-Seob Choi; Whi-Young Kim
Journal:  J Biomed Biotechnol       Date:  2011-06-12

2.  Effect of magnetic field exposure on anchorage-independent growth of a promoter-sensitive mouse epidermal cell line (JB6).

Authors:  J E Snawder
Journal:  Environ Health Perspect       Date:  1999-03       Impact factor: 9.031

3.  Ultrafast and low-energy switching in voltage-controlled elliptical pMTJ.

Authors:  Jiefang Deng; Gengchiau Liang; Gaurav Gupta
Journal:  Sci Rep       Date:  2017-11-29       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.