Literature DB >> 7878210

Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy.

V Rudat1, M Flentje, D Oetzel, M Menke, W Schlegel, M Wannenmacher.   

Abstract

The influence of patient immobilization error on 3D planned conformal radiation therapy in tumors of the thorax and pelvis was studied. The mean positioning error in 43 patients with carcinomas of the thorax and pelvis undergoing 3D conformal radiotherapy (laser supported alignment, no immobilization device) was measured. A total of 194 portal films were superposed with the corresponding simulator radiographs according to anatomic landmarks and using a subtrascope. x-, y- and z-axis deviation was determined within a coordinate system. Using specialized software including Fourier transformation the mean positioning error was employed to recalculate the dose distributions of all cases under the influence of random (Gaussian) immobilization uncertainty. The mean two-dimensional positioning error using the data from all patients was 5.5 (+/- 3.7) mm. The distribution was Gaussian. Dose volume histograms (DVHs) of each patient with and without consideration of positioning uncertainty were compared on the base of tumor control probability estimations (TCP) using published DVH reduction and TCP algorithms. Inclusion of the positioning error resulted in a mean decrease in TCP (given as the difference between the TCP assuming no positioning error and the TCP modified by the positioning error) of 2% in a series of esophagus carcinomas and of 5% in the prostate carcinomas when looking at gross tumor volume (GTV), only. Planning target volume (PTV) exhibited a relative decrease in TCP of 5% and 11%, respectively.

Entities:  

Mesh:

Year:  1994        PMID: 7878210     DOI: 10.1016/0167-8140(94)90086-8

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  5 in total

1.  Image-guided intensity-modulated radiotherapy of prostate cancer: Analysis of interfractional errors and acute toxicity.

Authors:  Volker Rudat; A Nour; M Hammoud; A Alaradi; A Mohammed
Journal:  Strahlenther Onkol       Date:  2015-11-06       Impact factor: 3.621

2.  Incorporating breath holding and image guidance in the adjuvant gastric cancer radiotherapy: a dosimetric study.

Authors:  Weigang Hu; Jinsong Ye; Jiazhou Wang; Qing Xu; Zhen Zhang
Journal:  Radiat Oncol       Date:  2012-06-20       Impact factor: 3.481

3.  Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins.

Authors:  Volker Rudat; Mohamed Hammoud; Yogin Pillay; Abdul Aziz Alaradi; Adel Mohamed; Saleh Altuwaijri
Journal:  Radiat Oncol       Date:  2011-08-24       Impact factor: 3.481

4.  [The conformal radiotherapy of localized prostatic carcinoma: acute tolerance and early efficacy].

Authors:  D Zierhut; M Flentje; G Sroka-Perez; V Rudat; R Engenhart-Cabillic; M Wannenmacher
Journal:  Strahlenther Onkol       Date:  1997-02       Impact factor: 4.033

5.  Assessment of robustness against setup uncertainties using probabilistic scenarios in lung cancer: a comparison of proton with photon therapy.

Authors:  Suliana Teoh; Ben George; Francesca Fiorini; Katherine A Vallis; Frank Van den Heuvel
Journal:  Br J Radiol       Date:  2020-02-04       Impact factor: 3.629

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.