Literature DB >> 7877207

Duplex ultrasonography: a noninvasive technique in monitoring of Le Veen shunt.

P Lucciarini1, G Schön, P Waldenberger, A Königsrainer.   

Abstract

Monitoring of peritoneovenous Le Veen shunt by duplex ultrasonography was first performed in 1993 in 10 patients. The duplex signal was picked up selectively in the venous tube and the peak velocity was measured at forced inspiration. Thirty-two examinations were performed. Of these, 13 had follow-up examinations by other modalities (radionuclide imaging, shuntography, or surgical exploration), all of which confirmed the findings of duplex ultrasonography. Shuntography was avoided in all instances with a patent shunt. Duplex ultrasonography allows noninvasive assessment of Le Veen shunt patency and appears reliable for determining the need for invasive diagnostic modalities or surgical shunt correction.

Entities:  

Mesh:

Year:  1994        PMID: 7877207     DOI: 10.7863/jum.1994.13.12.959

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  1 in total

1.  Peritoneovenous shunt scintigraphy to assess shunt patency in patients with refractory ascites.

Authors:  Raja Senthil; Sumati Sundaraiya; Rajasekhar Perumalla; Mohamed Rela
Journal:  J Clin Exp Hepatol       Date:  2013-06-27
  1 in total