Literature DB >> 7876415

Influence of temperature and relative humidity on early bond strengths to dentine.

M F Burrow1, Y Taniguchi, T Nikaido, M Satoh, N Inai, J Tagami, T Takatsu.   

Abstract

The effect of temperature and relative humidity (RH) on the early tensile bond strengths to bovine dentine of two bonding systems (Liner Bond System, and Scotchbond Multi-purpose), and an experimental system (KB-110) were tested. Two environmental conditions, room temperature (23 degrees C/50% RH) and oral temperature (30 degrees C/80% RH), were used in a controlled temperature and humidity chamber. Bond strengths were recorded immediately after, 10 min and 24 h following light curing. The tensile bond strengths did not vary between the two test conditions, but the mode of fracture was observed to change. The 30 degrees C/80% RH condition exhibited a slightly greater degree of adhesive type failures compared with the 23 degrees C/50% RH group. This was particularly so for the experimental system, indicating that different bonding systems may be more or less sensitive to changes in RH and temperature. Failures occurred partially or totally within the resin composite at the early test times, and it was concluded that the bond strengths of the systems tested tended to exceed the early cohesive strengths of the resin composite.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7876415     DOI: 10.1016/0300-5712(95)90659-6

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  4 in total

1.  Time-dependent effect of refrigeration on viscosity and conversion kinetics of dental adhesive resins.

Authors:  André L Faria-E-Silva; Evandro Piva; Rafael R Moraes
Journal:  Eur J Dent       Date:  2010-04

2.  A novel method for removing the collagen network from acid-etched dentin by neodymium:yttrium-aluminum-garnet laser.

Authors:  Raad Niama Dayem
Journal:  Lasers Med Sci       Date:  2007-12-12       Impact factor: 3.161

3.  Microtensile dentin bond strength of fifth with five seventh-generation dentin bonding agents after thermocycling: An in vitro study.

Authors:  Bruhvi Poptani; K S Gohil; Jaishree Ganjiwale; Manisha Shukla
Journal:  Contemp Clin Dent       Date:  2012-09

4.  Effect of storage temperature on bond strength of a self-etch adhesive system to pulp chamber dentin.

Authors:  Nazmiye Donmez; Hale Ari; Sema Belli
Journal:  Eur J Dent       Date:  2009-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.