Does airway pressure release ventilation alter lung function after acute lung injury?

R A Smith1, D B Smith.   

Abstract

BACKGROUND: During airway pressure release ventilation (APRV), tidal ventilation occurs between the increased lung volume established by the application of continuous positive airway pressure (CPAP) and the relaxation volume of the respiratory system. Concern has been expressed that release of CPAP may cause unstable alveoli to collapse and not reinflate when airway pressure is restored.
OBJECTIVE: To compare pulmonary mechanics and oxygenation in animals with acute lung injury during CPAP with and without APRV.
DESIGN: Experimental, subject-controlled, randomized crossover investigation.
SETTING: Anesthesiology research laboratory, University of South Florida College of Medicine Health Sciences Center.
SUBJECTS: Ten pigs of either sex.
INTERVENTIONS: Acute lung injury was induced with an intravenous infusion of oleic acid (72 micrograms/kg) followed by randomly alternated 60-min trials of CPAP with and without APRV. Continuous positive airway pressure was titrated to produce an arterial oxyhemoglobin saturation of at least 95% (FIO2 = 0.21). Airway pressure release ventilation was arbitrarily cycled to atmospheric pressure 10 times per minute with a release time titrated to coincide with attainment of respiratory system relaxation volume. MEASUREMENTS: Cardiac output, arterial and mixed venous pH, blood gas tensions, hemoglobin concentration and oxyhemoglobin saturation, central venous pressure, pulmonary and systemic artery pressures, pulmonary artery occlusion pressure, airway gas flow, airway pressure, and pleural pressure were measured. Tidal volume (VT), dynamic lung compliance, intrapulmonary venous admixture, pulmonary vascular resistance, systemic vascular resistance, oxygen delivery, oxygen consumption, and oxygen extraction ratio were calculated. MAIN
RESULTS: Central venous infusion of oleic acid reduced PaO2 from 94 +/- 4 mm Hg to 52 +/- 9 mm Hg (mean +/- 1 SD) (p < 0.001) and dynamic lung compliance from 40 +/- 6 mL/cm H2O to 20 +/- 6 mL/cm H2O (p = 0.002) and increased venous admixture from 13 +/- 3% to 32 +/- 7% (p < 0.001) in ten swine weighing 33.3 +/- 4.1 kg while they were spontaneously breathing room air. After induction of lung injury, the swine received CPAP (14.7 +/- 3.3 cm H2O) with or without APRV at 10 breaths per minute with a release time of 1.1 +/- 0.2 s. Although mean transpulmonary pressure was significantly greater during CPAP (11.7 +/- 3.3 cm H2O) vs APRV (9.4 +/- 3.8 cm H2O) (p < 0.001), there were no differences in hemodynamic variables. PaCO2 was decreased and pHa was increased during APRV vs CPAP (p = 0.003 and p = 0.005). PaO2 declined from 83 +/- 4 mm Hg to 79 +/- 4 mm Hg (p = 0.004) during APRV, but arterial oxyhemoglobin saturation (96.6 +/- 1.4% vs 96.9 +/- 1.3%) did not. Intrapulmonary venous admixture (9 +/- 3% vs 11 +/- 5%) and oxygen delivery (469 +/- 67 mL/min vs 479 +/- 66 mL/min) were not altered. After treatment periods and removal of CPAP for 60 min, PaO2 and intrapulmonary venous admixture returned to baseline values. DISCUSSION: Intrapulmonary venous admixture, arterial oxyhemoglobin saturation, and oxygen delivery were maintained by APRV at levels induced by CPAP despite the presence of unstable alveoli. Decrease in PaO2 was caused by increase in pHa and decrease in PaCO2, not by deterioration of pulmonary function. We conclude that periodic decrease of airway pressure created by APRV does not cause significant deterioration in oxygenation or lung mechanics.

Entities:  

Mesh:

Year:  1995        PMID: 7874957     DOI: 10.1378/chest.107.3.805

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  4 in total

Review 1.  Airway pressure release ventilation and biphasic positive airway pressure: a systematic review of definitional criteria.

Authors:  Louise Rose; Martyn Hawkins
Journal:  Intensive Care Med       Date:  2008-07-17       Impact factor: 17.440

Review 2.  Myths and Misconceptions of Airway Pressure Release Ventilation: Getting Past the Noise and on to the Signal.

Authors:  Penny Andrews; Joseph Shiber; Maria Madden; Gary F Nieman; Luigi Camporota; Nader M Habashi
Journal:  Front Physiol       Date:  2022-07-25       Impact factor: 4.755

Review 3.  Partial ventilatory support modalities in acute lung injury and acute respiratory distress syndrome-a systematic review.

Authors:  Sarah M McMullen; Maureen Meade; Louise Rose; Karen Burns; Sangeeta Mehta; Robert Doyle; Dietrich Henzler
Journal:  PLoS One       Date:  2012-08-16       Impact factor: 3.240

Review 4.  The 30-year evolution of airway pressure release ventilation (APRV).

Authors:  Sumeet V Jain; Michaela Kollisch-Singule; Benjamin Sadowitz; Luke Dombert; Josh Satalin; Penny Andrews; Louis A Gatto; Gary F Nieman; Nader M Habashi
Journal:  Intensive Care Med Exp       Date:  2016-05-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.