Femoral strain distribution and subsidence after physiological loading of a cementless canine femoral prosthesis: the effects of implant orientation, canal fill, and implant fit.

R T Pernell1, R S Gross, J L Milton, R D Montgomery, J G Wenzel, C G Savory, H M Aberman.   

Abstract

Twelve normal greyhound femora were divided into three groups. In group one, femoral stems were placed in neutral position with maximal fill. Group two had undersized femoral stems placed in neutral position. Group three had undersized femoral stems placed in varus position. Intact and implanted femora were loaded from 10 newtons (N) to 300 N in axial compression at a rate of 25 N/s for 10 replications. A strain gauge analysis showed that the strain distribution of all implanted femora were substantially different from intact femora, but femora with large implants placed in neutral position had the least amount of deviation from normal. An undersized stem in neutral position had significantly less compressive longitudinal strains along the proximomedial and proximocranial cortices. An undersized stem in varus position improved implant fit along the proximomedial and distolateral cortices, which resulted in increased tensile hoop strains. There were multiple significant correlations between the strain data and implantation variables (implant alignment, canal fill, and implant fit). Subsidence was significantly greater for the undersized implant in neutral position. There was not a difference in subsidence between the large neutral and varus groups. The most important variable that decreased subsidence was increased lateral implant fit (r = -0.86, P = .0003).

Entities:  

Mesh:

Year:  1994        PMID: 7871714     DOI: 10.1111/j.1532-950x.1994.tb00512.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  2 in total

1.  Influence of cementless femoral stems inserted in varus on functional outcome in primary total hip arthroplasty.

Authors:  Justin de Beer; Scott McKenzie; Matthias Hubmann; Danielle Petruccelli; Mitchell Winemaker
Journal:  Can J Surg       Date:  2006-12       Impact factor: 2.089

2.  The Effects of Interlocking a Universal Hip Cementless Stem on Implant Subsidence and Mechanical Properties of Cadaveric Canine Femora.

Authors:  Yonathan Buks; Kirk L Wendelburg; Susan M Stover; Tanya C Garcia-Nolen
Journal:  Vet Surg       Date:  2016-01-15       Impact factor: 1.495

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.