Literature DB >> 7870662

Hepatic blood flow measurements and indocyanine green kinetics in a chronic dog model.

A Skerjanec1, D W O'Brien, T K Tam.   

Abstract

The objective of this study was to compare hepatic blood flow measurements using ultrasonic flow probes and ICG in a conscious dog model and to evaluate whether ICG can be used to estimate relative change in hepatic blood flow. Seven mongrel dogs (3 M, 4 F, BW = 21 +/- 1.8 kg, Hct = 0.39 +/- 0.05) were used in the study. Catheters were surgically inserted into carotid artery and portal, hepatic and jugular vein. Transit-time ultrasonic flow probes were implanted around the portal vein and hepatic artery. After two weeks of recovery, a single i.v. bolus dose of ICG (0.5 mg/kg) was administered to each dog. The disposition profiles for ICG in the four catheters were measured for 15 minutes and the hepatic blood flow reading from the probes recorded. Jugular vein ICG blood clearance (Cl = 5.9 +/- 1.1 ml/min/kg) was low compared to the electronically measured hepatic blood flow rate (Q = 27.8 +/- 9.1 ml/min/kg). Extraction ratios (E = 0.15 +/- 0.05) estimated using data from the inlet and the outlet of the liver were consistent with the clearance values, suggesting that ICG is not highly extracted by dog livers. Three dogs were used in experiments where liver blood flow was increased by food intake. Consistent with characteristics of low extraction ratio drugs, ICG was insensitive to blood flow changes while there was an overall increase in electronically measured liver blood flow of 30%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7870662     DOI: 10.1023/a:1018928930617

Source DB:  PubMed          Journal:  Pharm Res        ISSN: 0724-8741            Impact factor:   4.200


  13 in total

1.  The use of indocyanine green in the measurement of hepatic blood flow and as a test of hepatic function.

Authors:  J CAESAR; S SHALDON; L CHIANDUSSI; L GUEVARA; S SHERLOCK
Journal:  Clin Sci       Date:  1961-08       Impact factor: 6.124

2.  Estimation of hepatic blood flow using a single injection dye clearance method.

Authors:  E F BANASZAK; W J STEKIEL; R A GRACE; J J SMITH
Journal:  Am J Physiol       Date:  1960-04

3.  Variability of indocyanine green pharmacokinetics in healthy adults.

Authors:  L A Bauer; J R Horn; K E Opheim
Journal:  Clin Pharm       Date:  1989-01

4.  Measuring bovine mammary gland blood flow using a transit time ultrasonic flow probe.

Authors:  R C Gorewit; M C Aromando; D G Bristol
Journal:  J Dairy Sci       Date:  1989-07       Impact factor: 4.034

5.  Physiological and pharmacological variability in estimated hepatic blood flow in man.

Authors:  T K Daneshmend; L Jackson; C J Roberts
Journal:  Br J Clin Pharmacol       Date:  1981-05       Impact factor: 4.335

6.  Methodological problems in the use of indocyanine green to estimate hepatic blood flow and ICG clearance in man.

Authors:  C Skak; S Keiding
Journal:  Liver       Date:  1987-06

7.  [Indocyanine green test in the dog].

Authors:  W Kraft; J Lechner; A M Vollmar; C Reusch; M Warmbier; E Lohss
Journal:  Tierarztl Prax       Date:  1991-08

8.  Comparative effects of halothane, isoflurane, and sevoflurane on the liver with hepatic artery ligation in the beagle.

Authors:  Y Fujita; K Kimura; H Hamada; M Takaori
Journal:  Anesthesiology       Date:  1991-08       Impact factor: 7.892

9.  Liver blood flow measurement in the rat. The electromagnetic versus the microsphere and the clearance methods.

Authors:  M J Daemen; H H Thijssen; H van Essen; H T Vervoort-Peters; F W Prinzen; H A Struyker Boudier; J F Smits
Journal:  J Pharmacol Methods       Date:  1989-07

10.  Hepatic plasma flow: accuracy of estimation from bolus injections of indocyanine green.

Authors:  F J Burczynski; K L Pushka; D S Sitar; C V Greenway
Journal:  Am J Physiol       Date:  1987-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.