Literature DB >> 7867327

Nickel release from metals, and a case of allergic contact dermatitis from stainless steel.

L Kanerva1, T Sipiläinen-Malm, T Estlander, A Zitting, R Jolanki, K Tarvainen.   

Abstract

The prevalence of allergic contact dermatitis (ACD) caused by nickel is increasing. The probable cause is the increased use of nickel-containing metals in intimate contact with the skin. The critical factor is the amount of nickel released from these metals (bioavailable nickel) onto the skin. In the present study, we determined, with flame atomic absorbtion spectrometry, the amount of nickel released into synthetic sweat from metal samples. The results of this method were compared with the results of the dimethylglyoxime (DMG) test, which is considered to be a reliable means of identifying whether nickel-containing metals may cause allergy symptoms in sensitive individuals. Out of 10 samples studied, only small amounts (< 0.5 microgram/cm2/week) were released from 2 samples, and the DMG test was negative. From 5 samples, more than 0.5 microgram/cm2/week was released, and the DMG test was positive. For 3 samples, however, the DMG test was negative, though the flame atomic absorption spectrometry test showed considerable release of nickel. Therefore, although the DMG test can be used as a first line test for determining nickel release, some DMG-negative metal materials probably induce nickel sensitization, and should by no means be advertised as safe in this respect. We also report a nickel-allergic patient who developed ACD from stainless steel, indicating that some types of stainless steel release enough nickel to elicit allergic symptoms.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7867327     DOI: 10.1111/j.1600-0536.1994.tb02023.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  9 in total

1.  First in-human randomized comparison of an anodized niobium stent versus a standard stainless steel stent--an intravascular ultrasound and angiographic two-center study: the VELA study.

Authors:  F Beier; M Gyöngyösi; T Raeder; E von Eckardstein-Thumb; W Sperker; P Albrecht; C Spes; D Glogar; H Mudra
Journal:  Clin Res Cardiol       Date:  2006-07-03       Impact factor: 5.460

2.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

3.  The impact of orthopedic device associated with carbonated hydroxyapatite on the oxidative balance: experimental study of bone healing rabbit model.

Authors:  Samira Jebahi; Riadh Nsiri; Mohammed Boujbiha; Ezedine Bouroga; Tarek Rebai; Hassib Keskes; Abdelfattah El Feki; Hassane Oudadesse; Hafed El Feki
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-10-02

4.  Orthopaedic surgery in a patient with metal sensitivity.

Authors:  Raviraj Adala; Murali Chakravarthy; Vijayakumar Srinivas; Sanjay Pai
Journal:  J Cutan Aesthet Surg       Date:  2011-01

5.  Nickel contact dermatitis from hypodermic needles.

Authors:  Vandana Mehta; Vani Vasanth; C Balachandran
Journal:  Indian J Dermatol       Date:  2011-03       Impact factor: 1.494

6.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

Review 7.  Chemokines Associated with Pathologic Responses to Orthopedic Implant Debris.

Authors:  Nadim J Hallab; Joshua J Jacobs
Journal:  Front Endocrinol (Lausanne)       Date:  2017-01-19       Impact factor: 5.555

8.  Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants.

Authors:  Lauryn Samelko; Marco S Caicedo; Joshua Jacobs; Nadim James Hallab
Journal:  PLoS One       Date:  2019-01-17       Impact factor: 3.240

9.  Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty.

Authors:  Nadim James Hallab; Marco Caicedo; Alison Finnegan; Joshua J Jacobs
Journal:  J Orthop Surg Res       Date:  2008-02-13       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.