Literature DB >> 7867140

Evaluation of the alkaline haematin D-575 method for haemoglobin estimation in east Africa.

O E Lema1, J Y Carter, P A Arube, C G Munafu, M W Wangai, P H Rees.   

Abstract

In many health facilities in east Africa, haemoglobin estimation is performed using visual colour comparison methods. Efforts to establish colorimetric methods face numerous constraints, including the unavailability of standards for quality control. In contrast, the alkaline haematin D-575 method for haemoglobin estimation is a colorimetric method that uses primary standards prepared from pure, crystalline chlorohaemin. There is no significant difference in the accuracy of the alkaline haematin D-575 method and that of the reference haemiglobincyanide method (P > 0.05), and the response of the alkaline haematin D-575 method is linear for serially diluted blood samples over the haemoglobin concentration range 19.6-3.3 g/dl (r = 0.994, y = 1.01 x - 0.3). The method has a precision of +/-0.3 g/dl (coefficient of variation = (1.8%) for whole blood, and is suitable for use with fixed-wavelength haemglobinometers (lambda = 565 nm) or with colorimeters at lambda = 580 nm. Stable quality control standards could be prepared at provincial, zonal, or reference laboratories and distributed regularly to outlying laboratories.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7867140      PMCID: PMC2486729     

Source DB:  PubMed          Journal:  Bull World Health Organ        ISSN: 0042-9686            Impact factor:   9.408


  4 in total

1.  Estimation of Haemoglobin by the Alkaline Haematin Method.

Authors:  J W Clegg; E J King
Journal:  Br Med J       Date:  1942-09-19

2.  Alkaline haematin D-575, a new tool for the determination of haemoglobin as an alternative to the cyanhaemiglobin method. II. Standardisation of the method using pure chlorohaemin.

Authors:  H U Wolf; W Lang; R Zander
Journal:  Clin Chim Acta       Date:  1984-01-16       Impact factor: 3.786

3.  Alkaline haematin D-575, a new tool for the determination of haemoglobin as an alternative to the cyanhaemiglobin method. I. Description of the method.

Authors:  R Zander; W Lang; H U Wolf
Journal:  Clin Chim Acta       Date:  1984-01-16       Impact factor: 3.786

4.  Lauryl sulphate haemoglobin: a non-hazardous substitute for HiCN in haemoglobinometry.

Authors:  S M Lewis; B Garvey; R Manning; S A Sharp; J Wardle
Journal:  Clin Lab Haematol       Date:  1991
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.