Literature DB >> 7864408

Reductions in platelet force development by cardiopulmonary bypass are associated with hemorrhage.

P E Greilich1, M E Carr, S L Carr, A S Chang.   

Abstract

Quantitative assessment of platelet dysfunction after cardiopulmonary bypass (CPB) and prediction of excessive microvascular bleeding remain elusive goals. We used a sensitive instrument capable of simultaneously measuring the force generated by platelets during plasma clot retraction and global clot strength. We hypothesized that CPB would significantly reduce these two variables. Platelet-rich plasma was obtained from eight patients undergoing aortocoronary revascularization prior to induction, after 90 min of CPB, and after protamine administration. Platelet force development was measured using a standardized technique that controlled for platelet number and permitted clot formation in the presence of heparin. Despite the presence of a measurable elastic modulus, platelet force development during bypass was abolished. Peak platelet force development after CPB was significantly lower than before CPB (5255 +/- 955 dynes vs 11,600 +/- 780 dynes, P = 0.01). The percent recovery (after/before bypass) of peak platelet force development inversely correlated with tube thoracostomy drainage during the first 24 h after placement (rs = -0.71, P = 0.048). This study demonstrates that CPB has dramatic effects on platelet force development. The correlation between the percent recovery of peak platelet force development and blood loss supports the clinical relevance of this measurement.

Entities:  

Mesh:

Year:  1995        PMID: 7864408     DOI: 10.1097/00000539-199503000-00005

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

1.  Antiplatelet drugs: mechanisms and risks of bleeding following cardiac operations.

Authors:  Victor A Ferraris; Suellen P Ferraris; Sibu P Saha
Journal:  Int J Angiol       Date:  2011-03

2.  Platelet retraction force measurements using flexible post force sensors.

Authors:  Xin M Liang; Sangyoon J Han; Jo-Anna Reems; Dayong Gao; Nathan J Sniadecki
Journal:  Lab Chip       Date:  2010-01-20       Impact factor: 6.799

3.  A Miniaturized Hemoretractometer for Blood Clot Retraction Testing.

Authors:  Zida Li; Xiang Li; Brendan McCracken; Yue Shao; Kevin Ward; Jianping Fu
Journal:  Small       Date:  2016-06-01       Impact factor: 13.281

4.  Platelet function in stored heparinised autologous blood is not superior to in patient platelet function during routine cardiopulmonary bypass.

Authors:  Rolf C G Gallandat Huet; Adrianus J de Vries; Vladimir Cernak; Ton Lisman
Journal:  PLoS One       Date:  2012-03-19       Impact factor: 3.240

Review 5.  Mechanobiology of platelets: techniques to study the role of fluid flow and platelet retraction forces at the micro- and nano-scale.

Authors:  Shirin Feghhi; Nathan J Sniadecki
Journal:  Int J Mol Sci       Date:  2011-12-07       Impact factor: 5.923

6.  Point-of-Care Testing of Hemostasis in Cardiac Surgery.

Authors:  Domenico Prisco; Rita Paniccia
Journal:  Thromb J       Date:  2003-05-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.