Literature DB >> 7863025

Flow velocity and volume measurement of superior and inferior mesenteric artery with cine phase contrast magnetic resonance imaging.

S Naganawa1, T G Cooper, G Jenner, E J Potchen, T Ishigaki.   

Abstract

The flow velocity and volume of the superior and inferior mesenteric arteries (SMA, IMA) were measured with cine phase contrast magnetic resonance (MR) imaging in five healthy volunteers. Each volunteer was first measured in a fasting state, and then one, two, and three hours after a meal. The average SMA flow volume of the volunteers was 230.3 +/- 46.8 ml/min (mean +/- standard error) during the fasting state, and 714.7 +/- 207.7 ml/min, 339.2 +/- 85.7 ml/min, and 263.8 +/- 21.0 ml/min, respectively, at one, two, and three hours postmeal. The increase at one hour postmeal was statistically significant (p < 0.05). The corresponding flow measurements in the IMA were 63.1 +/- 11.2 ml/min, 67.6 +/- 11.2 ml/min, 57.9 +/- 8.6 ml/min, and 53.2 +/- 6.8 ml/min. These values do not represent a statistically significant flow volume change in the IMA. In all volunteers, the SMA volumetric flow increased the most one hour after the food challenge (72-400% relative to baseline). Diastolic velocity in the SMA increased significantly one hour postmeal, but systolic velocity did not change significantly. The IMA did not demonstrate a significant change in either systolic or diastolic velocity. The difference between the SMA and IMA in the way of reacting against the food challenge is thought to represent the difference between the requirements of small and large intestine for blood supply after the food challenge. These data demonstrate the possibility of this modality for the assessment of conditions such as chronic mesenteric ischemia.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7863025

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  2 in total

1.  New Insights in Abdominal Pain in Paroxysmal Nocturnal Hemoglobinuria (PNH): A MRI Study.

Authors:  Francesco De Cobelli; Giulio Pezzetti; Sergio Margari; Antonio Esposito; Francesco Giganti; Giulia Agostini; Alessandro Del Maschio
Journal:  PLoS One       Date:  2015-04-21       Impact factor: 3.240

2.  Optimal Plane Selection for Measuring Post-prandial Blood Flow Increase within the Superior Mesenteric Artery: Analysis Using 4D Flow and Computational Fluid Dynamics.

Authors:  Masataka Sugiyama; Yasuo Takehara; Masanori Kawate; Naoki Ooishi; Masaki Terada; Haruo Isoda; Harumi Sakahara; Shinji Naganawa; Kevin M Johnson; Oliver Wieben; Tetsuya Wakayama; Atsushi Nozaki; Hiroyuki Kabasawa
Journal:  Magn Reson Med Sci       Date:  2020-01-31       Impact factor: 2.471

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.