An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty.

S Nakamura1, D J Mahon, B Maheswaran, D E Gutfinger, A Colombo, J M Tobis.   

Abstract

OBJECTIVES: This study attempted to determine why there is a discrepancy between angiographic and intravascular ultrasound measurements after coronary balloon angioplasty.
BACKGROUND: Previous studies have shown a poor correlation between angiographic and intravascular ultrasound measurements after percutaneous coronary balloon angioplasty.
METHODS: After successful balloon angioplasty, 91 lesions in 84 patients were studied by intravascular ultrasound. Plaque morphology on intravascular ultrasound was classified as demonstrating a superficial injury if there was either no fracture or only a small tear that did not extend to the media versus a deep injury defined as the presence of a plaque fracture that reached the media. Measurements of minimal lumen diameter were compared between angiography and intravascular ultrasound.
RESULTS: On ultrasound imaging, a superficial injury pattern was observed in 44 lesions, whereas a deep injury was seen in 47 lesions. There were no statistical differences at baseline in patient or lesion characteristics. In the superficial injury group there was a significant correlation between angiography and intravascular ultrasound for minimal lumen diameter (r = 0.67) and lumen cross-sectional area (r = 0.69). In the deep injury group there was a poor correlation for minimal lumen diameter (r = 0.05) and lumen cross-sectional area (r = 0.28). After balloon angioplasty, the angiographic appearance showed a normal contour in 34%, the presence of dissection in 38% or a hazy appearance in 23%. On ultrasound imaging after angioplasty, the superficial injury group comprised 65% of lesions with a normal angiographic appearance and 67% of lesions with a hazy appearance, whereas 77% of lesions with an angiographic diagnosis of dissection were in the deep injury group by ultrasound (p = 0.0005).
CONCLUSIONS: These observations suggest that the discrepancies between angiographic and ultrasound measurements are due to differences in plaque morphology created by balloon dilation. Superficial injuries demonstrate similar results by angiography or ultrasound, whereas a deep injury to the plaque produces a difference in measurements between angiography and ultrasound. When angiography reveals a dissection, there is a high probability that intravascular ultrasound will demonstrate a plaque fracture extending to the media.

Entities:  

Mesh:

Year:  1995        PMID: 7860907     DOI: 10.1016/0735-1097(94)00453-W

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  5 in total

1.  Factors influencing the intravascular ultrasound dimensions and areas measured using mechanical transducers.

Authors:  V Bhargava; W F Penny; A Arbab-Zadeh
Journal:  Int J Card Imaging       Date:  1996-12

2.  Effect of balloon inflation time on expansion of sirolimus-eluting stent.

Authors:  Tatsuhiko Asano; Yoshio Kobayashi; Kenichi Fukushima; Yo Iwata; Hideki Kitahara; Naoki Ishio; Takashi Nakayama; Nakabumi Kuroda; Issei Komuro
Journal:  Heart Vessels       Date:  2009-09-27       Impact factor: 2.037

3.  Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study.

Authors:  A L Gaster; U Slothuus Skjoldborg; J Larsen; L Korsholm; C von Birgelen; S Jensen; P Thayssen; K E Pedersen; T H Haghfelt
Journal:  Heart       Date:  2003-09       Impact factor: 5.994

4.  Comparison of Two Different Strategies of Intravascular Ultrasound Guidance during Percutaneous Coronary Intervention; Routine versus Selective.

Authors:  Jae-Bin Seo; Kyung Woo Park; Hae-Young Lee; Hyun-Jae Kang; Bon-Kwon Koo; Sang-Hyun Kim; Hyo-Soo Kim
Journal:  Korean Circ J       Date:  2013-05-31       Impact factor: 3.243

5.  Adjunctive intra-coronary imaging for the assessment of coronary artery disease.

Authors:  Nikunj Shah; Bassey Ussen; Michael Mahmoudi
Journal:  JRSM Cardiovasc Dis       Date:  2016-07-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.