Literature DB >> 7858770

Head-to-head comparison between technetium-99m-sestamibi and thallium-201 tomographic imaging for the detection of coronary artery disease using combined dipyridamole-exercise stress.

M J Cramer1, J F Verzijlbergen, E E Van der Wall, M G Niemeyer, A H Zwinderman, C A Ascoop, E J Pauwels.   

Abstract

AIM: The purpose of this study was a head-to-head comparison of tomographic imaging (SPECT) with technetium-99m (Tc-99m)-sestamibi and thallium-201 (Tl-201) using dipyridamole-low-level bicycle exercise stress for the assessment of coronary artery disease.
METHODS: We studied 38 consecutive patients referred for the evaluation of chest pain who had undergone coronary angiography. The patients were randomly allocated to Tc-99m-sestamibi SPECT followed by Tl-201 SPECT or vice versa. The accuracy of both tracers in detecting significant coronary artery disease (> 50% luminal stenosis) was 87% (95% confidence interval 72-96%). Only two patients were classified differently by the two methods.
RESULTS: On a segmental basis, good agreement was found between Tc-99m-sestamibi and Tl-201 for both the localization and the nature of perfusion defects (reversible or persistent) identified (Cohen's kappa = 0.67).
CONCLUSION: No clinically relevant differences in diagnostic accuracy were demonstrated between Tc-99m-sestamibi and Tl-201 SPECT using combined dipyridamole-exercise stress for the evaluation of coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7858770

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  7 in total

Review 1.  Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.

Authors:  P Kailasnath; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

Review 2.  Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging.

Authors:  C Y Loong; C Anagnostopoulos
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

3.  Detection of coronary artery disease: comparison between technetium 99m-labeled sestamibi single-photon emission computed tomography and two-dimensional echocardiography with dipyridamole low-level exercise-stress.

Authors:  M J Cramer; E E van der Wall; W Jaarsma; J F Verzijlbergen; M G Niemeyer; A H Zwinderman; E K Pauwels
Journal:  J Nucl Cardiol       Date:  1996 Sep-Oct       Impact factor: 5.952

4.  Dual isotope stress Tl-201 and rest Tc-99m CZT SPECT: Are we truly leveraging CZT technology?

Authors:  Saurabh Malhotra; Rami Doukky
Journal:  J Nucl Cardiol       Date:  2018-03-06       Impact factor: 5.952

5.  A comparative evaluation of Tl-201 and Tc-99m sestamibi myocardial perfusion spect imaging in diabetic patients.

Authors:  Ozgür Omür; Zehra Ozcan; Murat Argon; Ebru Tani Acar
Journal:  Int J Cardiovasc Imaging       Date:  2007-06-19       Impact factor: 2.357

Review 6.  Myocardial perfusion scintigraphy: the evidence.

Authors:  S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

7.  What is the best myocardial perfusion protocol in diabetic patients?

Authors:  Leo H B Baur
Journal:  Int J Cardiovasc Imaging       Date:  2007-09-01       Impact factor: 2.357

  7 in total