A sheep model for the study of hemorheology with assisted circulation. Effect of an axial flow blood pump.

M V Kameneva1, J F Antaki, K C Butler, M J Watach, R L Kormos, B P Griffith, H S Borovetz.   

Abstract

Hemorheologic investigations were performed on nine sheep during the in vivo evaluation of a new axial flow ventricular assist device, the Nimbus AxiPump (Nimbus, Inc., Rancho Cordova, CA). Blood hematocrit, plasma and whole blood viscosity, red blood cell (RBC) deformability and aggregation, plasma fibrinogen, and free hemoglobin (hemolysis) levels were measured. Changes in the main rheologic parameters of sheep blood relative to the pre-implant values were minor and transient. The exception was RBC aggregation, which appeared on the third day of implantation. (Sheep blood does not normally demonstrate RBC aggregation.) Sheep RBCs started to form classic rouleaux typically on the third post-operative day simultaneously with increasing fibrinogen level. To investigate the relative effects of mechanical stress and elevated fibrinogen levels on RBC aggregability, in vitro studies were conducted with blood from control sheep. These studies indicated that neither mechanical trauma nor elevated fibrinogen alone caused RBC aggregation as seen in vivo. However, combined mechanical stress and elevated fibrinogen did cause this unusual effect for sheep blood.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7858332

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Biocompatibility assessment of the first generation PediaFlow pediatric ventricular assist device.

Authors:  Carl A Johnson; Stijn Vandenberghe; Amanda R Daly; Joshua R Woolley; Shaun T Snyder; Josiah E Verkaik; Sang-Ho Ye; Harvey S Borovetz; James F Antaki; Peter D Wearden; Marina V Kameneva; William R Wagner
Journal:  Artif Organs       Date:  2011-01       Impact factor: 3.094

2.  Pre-clinical Implants of the Levitronix PediVAS® Pediatric Ventricular Assist Device - Strategy for Regulatory Approval.

Authors:  Timothy M Maul; Ergin Kocyildirim; John D Marks; Shawn G Bengston; Salim E Olia; Patrick M Callahan; Marina V Kameneva; Stephen Franklin; Harvey S Borovetz; Kurt A Dasse; Peter D Wearden
Journal:  Cardiovasc Eng Technol       Date:  2011-10-27       Impact factor: 2.495

Review 3.  Mechanical blood trauma in assisted circulation: sublethal RBC damage preceding hemolysis.

Authors:  Salim E Olia; Timothy M Maul; James F Antaki; Marina V Kameneva
Journal:  Int J Artif Organs       Date:  2016-03-30       Impact factor: 1.595

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.