A knowledge-based system for the interpretation of flow cytometry data in leukemias and lymphomas.

L W Diamond1, D T Nguyen, M Andreeff, R L Maiese, R C Braylan.   

Abstract

Flow cytometry immunophenotyping and analysis of DNA ploidy and proliferative activity have become extremely helpful techniques for diagnosing and subclassifying hematopoietic cell populations in a modern, full-service hematopathology laboratory. The number of physicians with special training in the interpretation of these studies is limited. A knowledge-based computer system has been designed to aid in the interpretation of immunophenotyping and DNA flow cytometry results in hematopoietic disease. The system, known as "Professor Fidelio," is a heuristic classification system that reasons on the basis of defined diagnostic patterns. In this study, Fidelio was tested as a stand-alone system on 366 specimens from two large tertiary medical centers. Fidelio's interpretation was considered to be appropriate in all cases. In 300 of 366 (82%) specimens, the system's interpretation agreed with the diagnosis of record. Many of the disagreements could be traced to errors in the recording of the original diagnosis and minor differences in diagnostic criteria between Fidelio's knowledge base and the criteria in use at the medical centers. When used in a stand-alone mode, Fidelio's interpretation was less specific than the diagnosis of record in certain lymphoproliferative disorders that require morphologic information for subclassification. Professor Fidelio is one module in a workstation for the diagnostic hematology laboratory. This workstation is designed for interpretive reporting, education, and database functions for clinical research. Clinical and morphologic information are shared between Fidelio and the other modules for peripheral blood analysis, bone marrow morphology, and lymph node interpretation by means of a relational database. The system will be useful in hospitals that lack individuals specially trained in flow cytometry.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7851162     DOI: 10.1002/cyto.990170310

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  3 in total

1.  Haematological validation of a computer-based bone marrow reporting system.

Authors:  D T Nguyen; L W Diamond; J D Cavenagh; R Parameswaran; J A Amess
Journal:  J Clin Pathol       Date:  1997-05       Impact factor: 3.411

Review 2.  Are normative expert systems appropriate for diagnostic pathology?

Authors:  L W Diamond; V G Mishka; A H Seal; D T Nguyen
Journal:  J Am Med Inform Assoc       Date:  1995 Mar-Apr       Impact factor: 4.497

3.  A survey of flow cytometry data analysis methods.

Authors:  Ali Bashashati; Ryan R Brinkman
Journal:  Adv Bioinformatics       Date:  2009-12-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.