Permanent pacemaker selection and subsequent survival in elderly Medicare pacemaker recipients.

G A Lamas1, C L Pashos, S L Normand, B McNeil.   

Abstract

BACKGROUND: Dual-chamber pacemakers have been in use for more than 15 years. Although they may confer a physiological advantage over single-chamber ventricular pacemakers, they are more expensive and have a generally shorter service life than single-chamber devices. We carried out the present study to identify patient subgroups who were preferentially receiving greater or lesser proportions of dual-chamber devices and to determine whether the selection of different types of pacemakers was associated with differences in mortality. METHODS AND
RESULTS: We analyzed a 20% random national sample of all Medicare beneficiaries aged 65 years or older who underwent initial placement of a permanent pacemaker and were discharged in 1988, 1989, or 1990 (n = 36,312). The minimum follow-up for vital status was 1 year. The relation of pacemaker type to patient and provider characteristics was determined using logistic regression analysis. The relation between pacemaker type and mortality was determined using the Cox proportional hazards method. The proportion of dual-chamber systems that were received increased from 27.2% in 1988 to 37.0% in 1990 (P < .001). Dual-chamber pacemaker recipients were younger (P < .001) than ventricular pacemaker recipients. Other independent correlates of dual-chamber pacemaker selection included male sex (odds ratio and 95% confidence intervals, 1.18 and 1.12 to 1.24, respectively), atrioventricular block (1.59 and 1.51 to 1.67), congestive heart failure (1.14 and 1.08 to 1.20), atrial fibrillation (0.36 and 0.34 to 0.39), and the presence of a major noncardiac diagnosis (0.86 and 0.83 to 0.89). Nonmedical predictors of dual-chamber pacemaker selection included Medicaid eligibility (0.78 and 0.71 to 0.86), implantation in the western United States (1.19 and 1.10 to 1.29), implantation by a rural provider (0.70 and 0.65 to 0.76), hospitalization in a 500-bed-or-larger hospital (1.20 and 1.13 to 1.28), hospitalization in a private hospital (1.19 and 1.10 to 1.28), or hospitalization in a hospital with a catheterization laboratory (1.47 and 1.38 to 1.56). Dual-chamber pacemaker selection was an independent predictor of survival at 1 year (0.82 and 0.77 to 0.87) and at 2 years (0.82 and 0.77 to 0.87) after controlling for potentially confounding patient-level and hospital-level characteristics.
CONCLUSIONS: The present study describes important variations in the clinical practice of cardiac pacing, many of which are not based on clinical characteristics. Furthermore, the selection of a dual-chamber pacemaker is associated with increased survival. These results underscore the need for prospective, outcome-based clinical trials of pacemaker mode selection.

Entities:  

Mesh:

Year:  1995        PMID: 7850942     DOI: 10.1161/01.cir.91.4.1063

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  19 in total

Review 1.  Window to the heart: the value of a native and paced QRS duration. Current perspective and review.

Authors:  Himanshu H Shukla; Erskine A James; John A Schutz; Benjamin F Lloyd; Greg C Flaker
Journal:  J Interv Card Electrophysiol       Date:  2003-12       Impact factor: 1.900

Review 2.  Right ventricular pacing, mechanical dyssynchrony, and heart failure.

Authors:  Alan J Bank; Ryan M Gage; Kevin V Burns
Journal:  J Cardiovasc Transl Res       Date:  2011-12-22       Impact factor: 4.132

Review 3.  Follow up and optimisation of cardiac pacing.

Authors:  Paul R Roberts
Journal:  Heart       Date:  2005-09       Impact factor: 5.994

4.  Sex differences in selection of pacemakers: retrospective observational study.

Authors:  R Schüppel; G Büchele; L Batz; W Koenig
Journal:  BMJ       Date:  1998-05-16

5.  Pacing mode and long-term survival in elderly patients with congestive heart failure: 1980-1985.

Authors:  P A Brady; W K Shen; S A Neubauer; S C Hammill; D O Hodge; D L Hayes
Journal:  J Interv Card Electrophysiol       Date:  1997-11       Impact factor: 1.900

Review 6.  Pacemaker mode selection and survival: a plea to apply the principles of evidence based medicine to cardiac pacing practice.

Authors:  G A Lamas
Journal:  Heart       Date:  1997-09       Impact factor: 5.994

7.  Stroke and atrial fibrillation in sick sinus syndrome.

Authors:  E Alt; G Lehmann
Journal:  Heart       Date:  1997-06       Impact factor: 5.994

8.  Cardiac Pacing for Bradycardia Support: Evidence-based Approach to Pacemaker Selection and Programming.

Authors:  Israel Galtes; Gervasio A. Lamas
Journal:  Curr Treat Options Cardiovasc Med       Date:  2004-10

Review 9.  Gender Disparities Across the Spectrum of Advanced Cardiac Therapies: Real or Imagined?

Authors:  Roberta C Bogaev
Journal:  Curr Cardiol Rep       Date:  2016-11       Impact factor: 2.931

10.  Long-term outcome of single-chamber atrial pacing compared with dual-chamber pacing in patients with sinus-node dysfunction and intact atrioventricular node conduction.

Authors:  Won Ho Kim; Boyoung Joung; Jaemin Shim; Jong Sung Park; Eui-Seock Hwang; Hui-Nam Pak; Sungsoon Kim; Moonhyoung Lee
Journal:  Yonsei Med J       Date:  2010-11       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.