Literature DB >> 7850168

Spectroscopic imaging of circular voxels with a two-dimensional Fourier-series window technique.

K Hendrich1, X Hu, R S Menon, H Merkle, P Camarata, R Heros, K Uğurbil.   

Abstract

Spatial localization with the spectroscopic imaging technique is normally implemented with the Fourier-transform approach, yielding rectangular voxels, with potentially significant cross-voxel contamination. Multidimensional Fourier-series window (FSW) is an alternate approach that generates single voxels of predetermined shape, with minimal out-of-voxel contamination. The spatial location of the voxel is shifted by means of postacquisition processing. A two-dimensional circular voxel is introduced, which for many in vivo applications is a good match of the region of interest. Phantom images illustrate the spatial distribution of signal intensity within the circular FSW voxels. Phantom spectroscopic studies show excellent spatial localization, with no detectable out-of-voxel contamination. The circular FSW voxel approach is implemented in human and animal model studies, demonstrating the technique's utility. This arbitrary shape approach can be extended to three dimensions, defining, for example, cylinders, spheres, or ellipsoids.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7850168     DOI: 10.1006/jmrb.1994.1128

Source DB:  PubMed          Journal:  J Magn Reson B        ISSN: 1064-1866


  11 in total

1.  In vitro and in vivo studies of 17O NMR sensitivity at 9.4 and 16.4 T.

Authors:  Ming Lu; Yi Zhang; Kamil Ugurbil; Wei Chen; Xiao-Hong Zhu
Journal:  Magn Reson Med       Date:  2012-07-06       Impact factor: 4.668

Review 2.  Assessing tissue metabolism by phosphorous-31 magnetic resonance spectroscopy and imaging: a methodology review.

Authors:  Yuchi Liu; Yuning Gu; Xin Yu
Journal:  Quant Imaging Med Surg       Date:  2017-12

3.  In vivo 31P MRS of human brain at high/ultrahigh fields: a quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T.

Authors:  Hongyan Qiao; Xiaoliang Zhang; Xiao-Hong Zhu; Fei Du; Wei Chen
Journal:  Magn Reson Imaging       Date:  2006-10-04       Impact factor: 2.546

4.  Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field.

Authors:  Xiao-Hong Zhu; Yi Zhang; Run-Xia Tian; Hao Lei; Nanyin Zhang; Xiaoliang Zhang; Hellmut Merkle; Kamil Ugurbil; Wei Chen
Journal:  Proc Natl Acad Sci U S A       Date:  2002-09-19       Impact factor: 11.205

5.  Quantitative analysis of spatial averaging effect on chemical shift imaging SNR and noise coherence with k-space sampling schemes.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Wei Chen
Journal:  Magn Reson Imaging       Date:  2019-03-31       Impact factor: 2.546

6.  Quantitative imaging of energy expenditure in human brain.

Authors:  Xiao-Hong Zhu; Hongyan Qiao; Fei Du; Qiang Xiong; Xiao Liu; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  Neuroimage       Date:  2012-02-17       Impact factor: 6.556

7.  Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

Authors:  Xiaoliang Zhang; Xiao-Hong Zhu; Runxia Tian; Yi Zhang; Hellmut Merkle; Wei Chen
Journal:  MAGMA       Date:  2003-07-04       Impact factor: 2.310

8.  New insights into central roles of cerebral oxygen metabolism in the resting and stimulus-evoked brain.

Authors:  Xiao-Hong Zhu; Nanyin Zhang; Yi Zhang; Kâmil Uğurbil; Wei Chen
Journal:  J Cereb Blood Flow Metab       Date:  2008-09-10       Impact factor: 6.200

9.  Simultaneous and noninvasive imaging of cerebral oxygen metabolic rate, blood flow and oxygen extraction fraction in stroke mice.

Authors:  Xiao-Hong Zhu; James M Chen; Tsang-Wei Tu; Wei Chen; Sheng-Kwei Song
Journal:  Neuroimage       Date:  2012-09-18       Impact factor: 6.556

10.  Interleaved 31 P MRS imaging of human frontal and occipital lobes using dual RF coils in combination with single-channel transmitter-receiver and dynamic B0 shimming.

Authors:  Byeong-Yeul Lee; Xiao-Hong Zhu; Myung Kyun Woo; Gregor Adriany; Scott Schillak; Wei Chen
Journal:  NMR Biomed       Date:  2017-10-26       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.