Literature DB >> 7849975

Intramedullary screw fixation of lateral malleolus fractures.

A B Bankston1, L D Anderson, P Nimityongskul.   

Abstract

A biomechanical evaluation of intramedullary versus buttress plate and lag screw fixation of lateral malleolus fractures is combined with a clinical evaluation of 44 patients with lateral malleolus fractures who underwent intramedullary screw fixation. The biomechanical study was performed in experimentally produced, Weber B, supination-eversion ankle fractures. The fractures were fixed with one of the two above fixation methods and then placed under a torsional load to failure. Sixteen cadaver ankles were tested as compared with native bone. The intramedullary screw provided 66.5% the resistance of torsion, and the buttress plate and lag screw provided 61.5% the resistance to torsion. There was no statistical difference between these two groups. The 44 fractures treated with an intramedullary screw were reviewed retrospectively. There was one failure of fixation, and one prominent hardware problem. Time to full weightbearing averaged 7.2 weeks. These results suggest that intramedullary screw fixation of noncomminuted lateral malleolus fractures provides stable fixation with good clinical results. This technique has the advantages of providing dynamic intramedullary fixation with limited surgical dissection and no subcutaneous hardware.

Entities:  

Mesh:

Year:  1994        PMID: 7849975     DOI: 10.1177/107110079401501105

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  8 in total

1.  Less is more: lag screw only fixation of lateral malleolar fractures.

Authors:  Paul B McKenna; Kieran O'shea; Tom Burke
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

2.  Minimally invasive plate osteosynthesis in type B fibular fractures versus open surgery.

Authors:  C Iacobellis; C Chemello; A Zornetta; R Aldegheri
Journal:  Musculoskelet Surg       Date:  2013-07-31

Review 3.  Intramedullary fixation of fibula fractures: A systematic review.

Authors:  Henrik C Bäcker; J Turner Vosseller
Journal:  J Clin Orthop Trauma       Date:  2021-04-24

4.  Biomechanical Study: Resistance Comparison of Posterior Antiglide Plate and Lateral Plate on Synthetic Bone Models Simulating Danis-Weber B Malleolar Fractures.

Authors:  Bruna Buscharino; Rafael Gioso Moretti; José Octavio Soares Hungria; Ralph Walter Christian; Marcelo Mercadante; Fábio Raia; Hélio Pekelman
Journal:  Rev Bras Ortop       Date:  2013-08-13

5.  One-Third Tubular Plate Remains a Clinically Good Option in Danis-Weber Type B Distal Fibular Fracture Fixation.

Authors:  Jae Hoon Ahn; Sung Hyun Cho; Mingi Jeong; Yoon-Chung Kim
Journal:  Orthop Surg       Date:  2021-10-27       Impact factor: 2.071

6.  Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?

Authors:  Sherif Hamdy Zawam; Mohamed Goda Mabrouk; Mahmoud Ahmed El-Desouky
Journal:  Int Orthop       Date:  2022-05-16       Impact factor: 3.479

Review 7.  Intramedullary fixation of distal fibular fractures: a systematic review of clinical and functional outcomes.

Authors:  Sameer Jain; Benjamin A Haughton; Christopher Brew
Journal:  J Orthop Traumatol       Date:  2014-10-11

8.  A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures.

Authors:  Paul J Switaj; Daniel Fuchs; Mohammed Alshouli; Avinash G Patwardhan; Leonard I Voronov; Muturi Muriuki; Robert M Havey; Anish R Kadakia
Journal:  J Orthop Surg Res       Date:  2016-09-15       Impact factor: 2.359

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.