Interdevice reliability and validity assessment of the Nicholas Hand-Held Dynamometer.

E Trudelle-Jackson1, A W Jackson, C M Frankowski, K M Long, N B Meske.   

Abstract

The Nicholas Hand-Held Dynamometer (HHD) has been shown to have excellent interday and intraday reliability when using the same HHD. Since clinics may have more than one HHD with which to evaluate patients, it would be of value to know if two identical HHDs measure the same variable consistently. The purpose of this investigation was to assess interdevice reliability of the Nicholas HHD as well as to determine its validity. Thirty healthy female subjects between the ages of 20 and 56 years (mean age = 28.4) were tested for hamstring strength. Three measurements of maximum hamstring contractions were obtained using the first HHD (Device A). The average of these three measurements was compared with the average of three measurements obtained after a brief rest using a second HHD (Device B). Measurements from the two HHDs were also compared with measurements obtained from a Kin-Com isokinetic dynamometer. The Kin-Com measurements were used as criteria to determine validity of the HHD. An intraclass correlation coefficient (ICC) calculated to determine reliability between the two HHDs was low (ICC = .58). Pearson product-moment correlation coefficients were calculated between the Kin-Com and each of the two HHDs. These values were .85 and .83 for Device A and B, respectively. Analysis of variance showed no significant difference between the Kin-Com and Device A but a significant difference between the Kin-Com and Device B (p < .001). Measurements obtained from two identical HHDs may be significantly different and should not be compared.

Entities:  

Mesh:

Year:  1994        PMID: 7849750     DOI: 10.2519/jospt.1994.20.6.302

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  10 in total

1.  Can a clinical test of hamstring strength identify football players at risk of hamstring strain?

Authors:  Anthony G Schache; Kay M Crossley; Ian G Macindoe; Brendan B Fahrner; Marcus G Pandy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-10       Impact factor: 4.342

2.  A new technique in double-bundle anterior cruciate ligament reconstruction with implant-free tibial fixation.

Authors:  Sylvio Noronha Sacramento; Eduardo Magalhães; Pascal Christel; Sheila Ingham; Thiago Yukio Fukuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-29       Impact factor: 4.342

3.  Exercises with partial vascular occlusion in patients with knee osteoarthritis: a randomized clinical trial.

Authors:  Flavio Fernandes Bryk; Amir Curcio Dos Reis; Deborah Fingerhut; Thomas Araujo; Marcela Schutzer; Ricardo de Paula Leite Cury; Aires Duarte; Thiago Yukio Fukuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-03-12       Impact factor: 4.342

4.  Clinimetric properties of hip abduction strength measurements obtained using a handheld dynamometer in individuals with a lower extremity amputation.

Authors:  Ruud A Leijendekkers; Gerben van Hinte; Amy D Sman; J Bart Staal; Maria W G Nijhuis-van der Sanden; Thomas J Hoogeboom
Journal:  PLoS One       Date:  2017-06-22       Impact factor: 3.240

5.  Isometric knee muscle strength measurement using a belt-stabilized hand-held dynamometer and an isokinetic dynamometer with and without trunk fixation: investigation of agreement of measurement values and factors influencing measurement.

Authors:  Munenori Katoh; Yukinobu Hiiragi; Masahiro Hirano; Masahiro Gomi; Ryosuke Tozawa; Yoshihito Sakai; Masaru Tanaka
Journal:  J Phys Ther Sci       Date:  2019-11-26

6.  Comparison of Common Methodologies for the Determination of Knee Flexor Muscle Strength.

Authors:  Dan I Ogborn; Alix Bellemare; Brittany Bruinooge; Holly Brown; Sheila McRae; Jeff Leiter
Journal:  Int J Sports Phys Ther       Date:  2021-04-01

7.  Measures of trunk muscle strength and their measurement properties: a protocol for a systematic review and narrative synthesis of clinical measures.

Authors:  Shouq Althobaiti; Alison Rushton; Deborah Falla; Nicola R Heneghan
Journal:  BMJ Open       Date:  2021-01-07       Impact factor: 2.692

8.  Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study.

Authors:  Benjamin F Mentiplay; Luke G Perraton; Kelly J Bower; Brooke Adair; Yong-Hao Pua; Gavin P Williams; Rebekah McGaw; Ross A Clark
Journal:  PLoS One       Date:  2015-10-28       Impact factor: 3.240

9.  RELIABILITY AND VALIDITY OF A MODIFIED ISOMETRIC DYNAMOMETER IN THE ASSESSMENT OF MUSCULAR PERFORMANCE IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

Authors:  Rodrigo Antunes de Vasconcelos; Débora Bevilaqua-Grossi; Antonio Carlos Shimano; Cleber Jansen Paccola; Tânia Fátima Salvini; Christiane Lanatovits Prado; Wilson A Mello Junior
Journal:  Rev Bras Ortop       Date:  2015-11-16

10.  Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis.

Authors:  Claudio Chamorro; Susan Armijo-Olivo; Carlos De la Fuente; Javiera Fuentes; Luis Javier Chirosa
Journal:  Open Med (Wars)       Date:  2017-10-17
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.