Literature DB >> 7845778

Quality-of-life during DDD and dual sensor VVIR pacing.

J Lukl1, V Doupal, P Heinc.   

Abstract

Twenty-one patients (mean age 68 +/- 8 years) with dual-sensor (QT+activity) DDDR pacemaker were randomly assigned to a crossover, double-blind study in order to evaluate their quality-of-life scores. All pacemakers were implanted for sick sinus syndrome (8 patients) or complete heart block (13 patients). The pacemakers were randomly programmed to VVIR or DDD pacing modes for 2-week periods and then the pacing mode was switched for another 2-week period. At the end of each period, the quality-of-life was evaluated by a questionnaire with regard to cardiovascular symptoms, physical activity, psychosocial and emotional functioning, and self-perceived health. Nineteen questions were scored 0-5 points each. Significant improvement in the mean total quality-of-life score (20.5 +/- 14.9 vs 34.8 +/- 17.4) as well as in dyspnea on effort, dizzy spells, palpitation, sweating, fatigue, lethargy, emotional functioning, and self-perceived health was observed during DDD compared to VVIR pacing. No question was scored in favor of VVIR pacing mode. Significant improvements during DDD pacing was demonstrated in all subgroups of patients (sick sinus syndrome, chronotropically competent and incompetent patients, and patients with high degree AV block). Eighteen patients preferred DDD pacing mode, while only one preferred VVIR pacing mode. Two remaining patients expressed no preference. The results suggest that DDD pacing offers better quality-of-life than dual sensor VVIR pacing in all subgroups of patients commonly indicated for pacemaker implantation.

Entities:  

Mesh:

Year:  1994        PMID: 7845778     DOI: 10.1111/j.1540-8159.1994.tb03760.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life?

Authors:  F Duru; S Büchi; R Klaghofer; H Mattmann; T Sensky; C Buddeberg; R Candinas
Journal:  Heart       Date:  2001-04       Impact factor: 5.994

2.  Ventricular pacemaker upgrade: experience, complications and recommendations.

Authors:  D J Hildick-Smith; M D Lowe; S A Newell; P M Schofield; L M Shapiro; D L Stone; A A Grace; M C Petch
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

3.  Comparison of dual chamber and ventricular rate responsive pacing in patients over 75 with complete heart block.

Authors:  M R Hargreaves; K M Channon; T R Cripps; M Gardner; O J Ormerod
Journal:  Br Heart J       Date:  1995-10

Review 4.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004

Review 5.  Indications for permanent pacing in dogs and cats.

Authors:  R A Santilli; F Giacomazzi; D M Porteiro Vázquez; M Perego
Journal:  J Vet Cardiol       Date:  2019-01-29       Impact factor: 1.701

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.