Literature DB >> 7845065

Non-invasive conductivity technique to detect changes in haematocrit: in vitro validation.

C G Olthof1, P M Kouw, A J Donker, J J de Lange, P M de Vries.   

Abstract

An on-line haematocrit measurement in extracorporeal circuits might be useful under some clinical circumstances (e.g. haemodialysis or cardiac surgery). As no such measurement exists, a device has been developed that makes it possible to detect haematocrit (Ht) continuously without a loss of blood. It is a multi-frequency system for the detection of electrical conductivities. The aim of this study was to investigate whether this device can measure Ht alterations properly. Ht alterations were induced by adding pure mannitol and 20% mannitol to fresh human blood. Furthermore, the effect of both mannitol substances on the intracellular ion content, intracellular conductivity and Ht were investigated. Alternations in Ht were established by the addition of 1000, 800, 600, 400, 200 and 0 mg of pure mannitol to 10 ml of fresh human blood, and 3.0, 2.5, 2.0, 2.0, 1.5, 1.0, 0.5 and 0 ml of 20% mannitol to fresh human blood until a total volume of 10 ml was achieved. Although their effects were significantly different, pure mannitol and 20% mannitol both caused a reduction in mean cellular volume, and thus in Ht. A highly significant correlation was found between Ht and intracellular conductivity (r = 0.90, p < 0.001). In addition to these effects, addition of pure mannitol and 20% mannitol had different effects on the intracellular ion content. Pure mannitol caused an increase in intracellular ion content due to a transcellular ion shift, whereas 20% mannitol induced a decrease. From this study, it can be concluded that the multi-frequency conductivity method observes changes in Ht (and intracellular fluid volume) in an accurate manner.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7845065     DOI: 10.1007/bf02515307

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  10 in total

1.  Electrical properties of tissue and cell suspensions.

Authors:  H P SCHWAN
Journal:  Adv Biol Med Phys       Date:  1957

2.  Measurement of transcellular fluid shift during haemodialysis. Part 2. In vitro and clinical evaluation.

Authors:  P M de Vries; J H Meijer; K Vlaanderen; V Visser; P L Oe; A J Donker; H Schneider
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

3.  Measurement of transcellular fluid shift during haemodialysis. Part 1. Method.

Authors:  J H Meijer; P M de Vries; H G Goovaerts; P L Oe; A J Donker; H Schneider
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

4.  Conductometric evaluation of interactions of electrolytes with D-glucitol, D-glucose, glycerol, D-mannitol, and sucrose.

Authors:  S P Moulik; D P Khan
Journal:  Carbohydr Res       Date:  1974-08       Impact factor: 2.104

5.  Mannitol and ionic shifts.

Authors:  O M Lilien; V A Andaloro
Journal:  Invest Urol       Date:  1970-05

6.  Increase in serum potassium resulting from the administration of hypertonic mannitol and other solutions.

Authors:  M Moreno; C Murphy; C Goldsmith
Journal:  J Lab Clin Med       Date:  1969-02

7.  Microprocessor-based system for measurement of electrical impedances during haemodialysis and in postoperative care.

Authors:  H G Goovaerts; F R de Vries; J H Meijer; P M de Vries; A J Donker; H Schneider
Journal:  Med Biol Eng Comput       Date:  1988-01       Impact factor: 2.602

Review 8.  Cellular handling of water.

Authors:  E Frömter
Journal:  Kidney Int Suppl       Date:  1987-08       Impact factor: 10.545

9.  Impedance of skeletal muscle from 1 Hz to 1 MHz.

Authors:  E Zheng; S Shao; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1984-06       Impact factor: 4.538

10.  Non-invasive conductivity method for detection of dynamic body fluid changes: in vitro and in vivo validation.

Authors:  C G Olthof; P M de Vries; P M Kouw; P L Oe; H Schneider; J J de Lange; A J Donker
Journal:  Nephrol Dial Transplant       Date:  1993       Impact factor: 5.992

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.