Literature DB >> 7842681

Nickel release from nickel-plated metals and stainless steels.

P Haudrechy1, J Foussereau, B Mantout, B Baroux.   

Abstract

Nickel release from nickel-plated metals often induces allergic contact dermatitis, but, for nickel-containing stainless steels, the effect is not well-known. In this paper, AISI 304, 316L, 303 and 430 type stainless steels, nickel and nickel-plated materials were investigated. 4 tests were performed: patch tests, leaching experiments, dimethylglyoxime (DMG) spot tests and electrochemical tests. Patch tests showed that 96% of the patients were intolerant to Ni-plated samples, and 14% to a high-sulfur stainless steel (303), while nickel-containing stainless steels with a low sulfur content elicited no reactions. Leaching experiments confirmed the patch tests: in acidic artificial sweat, Ni-plated samples released about 100 micrograms/cm2/week of nickel, while low-sulfur stainless steels released less than 0.03 microgram/cm2/week of nickel, and AISI 303 about 1.5 micrograms/cm2/week. Attention is drawn to the irrelevance of the DMG spot test, which reveals Ni present in the metal bulk but not its dissolution rate. Electrochemical experiments showed that 304 and 316 grades remain passive in the environments tested, while Ni-plated steels and AISI 303 can suffer significant cation dissolution. Thus, Ni-containing 304 and 316 steels should not induce contact dermatitis, while 303 should be avoided. A reliable nitric acid spot test is proposed to distinguish this grade from other stainless steels.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7842681     DOI: 10.1111/j.1600-0536.1994.tb01997.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  9 in total

1.  In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation.

Authors:  Nadim James Hallab; Marco Caicedo; Rachel Epstein; Kyron McAllister; Joshua J Jacobs
Journal:  J Biomed Mater Res A       Date:  2010-02       Impact factor: 4.396

Review 2.  [Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction?].

Authors:  P Thomas; J Geier; H Dickel; T Diepgen; U Hillen; B Kreft; A Schnuch; C Szliska; V Mahler
Journal:  Orthopade       Date:  2015-11       Impact factor: 1.087

3.  Cytotoxicity study of plasma-sprayed hydroxyapatite coating on high nitrogen austenitic stainless steels.

Authors:  C P O Ossa; S O Rogero; A P Tschiptschin
Journal:  J Mater Sci Mater Med       Date:  2006-11-22       Impact factor: 3.896

4.  Occupational contact dermatitis to nickel: experience of the British dermatologists (EPIDERM) and occupational physicians (OPRA) surveillance schemes.

Authors:  K W Shum; J D Meyer; Y Chen; N Cherry; D J Gawkrodger
Journal:  Occup Environ Med       Date:  2003-12       Impact factor: 4.402

5.  Orthopaedic surgery in a patient with metal sensitivity.

Authors:  Raviraj Adala; Murali Chakravarthy; Vijayakumar Srinivas; Sanjay Pai
Journal:  J Cutan Aesthet Surg       Date:  2011-01

6.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

Review 7.  Chemokines Associated with Pathologic Responses to Orthopedic Implant Debris.

Authors:  Nadim J Hallab; Joshua J Jacobs
Journal:  Front Endocrinol (Lausanne)       Date:  2017-01-19       Impact factor: 5.555

8.  Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants.

Authors:  Lauryn Samelko; Marco S Caicedo; Joshua Jacobs; Nadim James Hallab
Journal:  PLoS One       Date:  2019-01-17       Impact factor: 3.240

9.  Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty.

Authors:  Nadim James Hallab; Marco Caicedo; Alison Finnegan; Joshua J Jacobs
Journal:  J Orthop Surg Res       Date:  2008-02-13       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.