Literature DB >> 7838048

A Monte Carlo study of accelerator head scatter.

E L Chaney1, T J Cullip, T A Gabriel.   

Abstract

The production of off-focus x rays in the head of a 6 MV linac has been investigated using the EGS4 Monte Carlo code. The purpose of the study was to identify the sources of off-focus radiation and the relative contribution for each source. Even though a particular energy and linac were modeled, the broad conclusions are expected to be general since the effects of head scatter are similar for most conventional head designs, regardless of manufacturer, energy, and model. The head components that were modeled include the exit window of the accelerating structure, target, beam stopper, flattening filter, monitor chamber, primary and secondary collimators, and air. Monoenergetic 6 MeV electrons were followed through the exit window, target, and beam stopper until all energy was expended. Primary- and higher-order x rays produced throughout the head were followed until they were either absorbed or passed through a plane at the isocenter. Sites of off-focus radiation were found to be diffusely distributed throughout the head, with the most intense sources being the primary collimator, flattening filter, and beam stopper. Data analysis shows that the collimator effect is determined primarily by the volume of the extended head-scatter source that is exposed to the point of measurement through the collimating system. The results of this study provide a rationale for developing extended source models to calculate the collimator factor for fields defined by arbitrary collimation. An additional advantage is an improvement in the agreement between measured and calculated isodose distributions.

Entities:  

Mesh:

Year:  1994        PMID: 7838048     DOI: 10.1118/1.597194

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Determination of radiotherapy X-ray spectra using a screen-film system.

Authors:  H M Garnica-Garza
Journal:  Med Biol Eng Comput       Date:  2008-09-09       Impact factor: 2.602

2.  Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators.

Authors:  Shigeo Anai; Hidetaka Arimura; Katsumasa Nakamura; Fujio Araki; Takaomi Matsuki; Hideki Yoshikawa; Satoshi Yoshidome; Yoshiyuki Shioyama; Hiroshi Honda; Nobuo Ikeda
Journal:  Radiol Phys Technol       Date:  2011-03-24

3.  Prediction of back-scatter radiations to a beam monitor chamber of medical linear accelerators by use of the digitized target-current-pulse analysis method.

Authors:  Yusuke Suzuki; Naoki Hayashi; Hideki Kato; Hiroshi Fukuma; Yasujiro Hirose; Makoto Kawano; Yoshio Nishii; Masaru Nakamura; Takashi Mukouyama
Journal:  Radiol Phys Technol       Date:  2012-10-25

4.  Quantitative analysis of in-air output ratio.

Authors:  Hisayuki Miyashita; Shogo Hatanaka; Yukio Fujita; Shimpei Hashimoto; Atsushi Myojyoyama; Hidetoshi Saitoh
Journal:  J Radiat Res       Date:  2013-01-04       Impact factor: 2.724

5.  Fidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams.

Authors:  Georgios Kalantzis; Jianguo Qian; Bin Han; Gary Luxton
Journal:  J Med Phys       Date:  2012-10

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  Effect of VERO pan-tilt motion on the dose distribution.

Authors:  Heru Prasetio; Indra Yohannes; Christoph Bert
Journal:  J Appl Clin Med Phys       Date:  2017-06-06       Impact factor: 2.102

8.  Detectors assessment for stereotactic radiosurgery with cones.

Authors:  Nicolas Garnier; Régis Amblard; Rémy Villeneuve; Rodolphe Haykal; Cécile Ortholan; Philippe Colin; Anaïs Gérard; Sarah Belhomme; Franck Mady; Mourad Benabdesselam; Benjamin Serrano
Journal:  J Appl Clin Med Phys       Date:  2018-09-14       Impact factor: 2.102

9.  A dosimetric evaluation of flattening filter-free volumetric modulated arc therapy in nasopharyngeal carcinoma.

Authors:  Guishan Fu; Minghui Li; Yixin Song; Jianrong Dai
Journal:  J Med Phys       Date:  2014-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.