Literature DB >> 7836537

Three-dimensional ultrasound in obstetrics and gynaecology: technique, possibilities and limitations.

H Steiner1, A Staudach, D Spitzer, H Schaffer.   

Abstract

Three-dimensional (3D) ultrasound offers several options extending conventional two-dimensional scanning. Various imaging modes are available. Three perpendicular planes displayed simultaneously can be rotated and translated in order to obtain accurate sections and suitable views needed for diagnosis and geometric measurements. 3D ultrasound tomography combines the advantages of ultrasound, e.g. safety, simplicity of application and inexpensiveness, with the advantages of sequentially depictable sections in numerous rotatable and translatable sections. Surface rendering gives detailed plastic images if there are surrounding layers of different echogenicity allowing for the definition of a certain threshold. Transparent modes provide an imaging of structures with a higher echogenicity in the interior of the object. A combination of the two modes sequentially definable by the sonographer allows for the optimal viewing of structures. These imaging modes are innovative features which have to be evaluated for clinical applicability and usefulness. Digital documentation of whole volumes enables full evaluation without loss of information at a later point. 3D technology provides an enormous number of technical options which have to be evaluated for their diagnostic significance and limitations in obstetrics and gynaecology.

Mesh:

Year:  1994        PMID: 7836537     DOI: 10.1093/oxfordjournals.humrep.a138793

Source DB:  PubMed          Journal:  Hum Reprod        ISSN: 0268-1161            Impact factor:   6.918


  9 in total

1.  Number and size of antral follicles as predictive factors in vitro fertilization and embryo transfer.

Authors:  M Pöhl; M Hohlagschwandtner; A Obruca; G Poschalko; M Weigert; W Feichtinger
Journal:  J Assist Reprod Genet       Date:  2000-07       Impact factor: 3.412

2.  Imaging comparison of basic cardiac views between two- and three-dimensional ultrasound in normal fetuses in anterior spine positions.

Authors:  Po-Hui Wang; Gin-Den Chen; Long-Yau Lin
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

3.  Potential of three-dimensional ultrasound in neonatal and paediatric neurosonography.

Authors:  M Riccabona; T R Nelson; C Weitzer; B Resch; D P Pretorius
Journal:  Eur Radiol       Date:  2003-03-06       Impact factor: 5.315

Review 4.  Three-dimensional imaging of the uterus: The value of the coronal plane.

Authors:  Lufee Wong; Nikki White; Jayshree Ramkrishna; E Araujo Júnior; Simon Meagher; Fabricio Da Silva Costa
Journal:  World J Radiol       Date:  2015-12-28

5.  Early diagnosis of conjoined twins using two-dimensional color Doppler and three-dimensional ultrasound.

Authors:  F Bonilla-Musoles; F Raga; F Bonilla; J Blanes; N G Osborne
Journal:  J Natl Med Assoc       Date:  1998-09       Impact factor: 1.798

6.  Using game controller as position tracking sensor for 3D freehand ultrasound imaging.

Authors:  Vei Siang Chan; Farhan Mohamed; Yusman Azimi Yusoff; Dyah Ekashanti Octorina Dewi; Alfiera Anuar; Mohamad Amir Shamsudin; Wey Sheng Mong
Journal:  Med Biol Eng Comput       Date:  2019-10-10       Impact factor: 2.602

7.  A theranostic 3D ultrasound imaging system for high resolution image-guided therapy.

Authors:  Hanna Bendjador; Josquin Foiret; Robert Wodnicki; Douglas N Stephens; Zoe Krut; Eun-Yeong Park; Zulma Gazit; Dan Gazit; Gadi Pelled; Katherine W Ferrara
Journal:  Theranostics       Date:  2022-06-27       Impact factor: 11.600

8.  INITIAL EXPERIENCE WITH 3D-ULTRASOUND AS AN ADJUNCT TO 2DULTRASOUND IN FETAL ANOMALY DIAGNOSIS IN A NIGERIAN DIAGNOSTIC FACILITY.

Authors:  J A Akinmoladun; V O Oboro; T I Adelakun
Journal:  Ann Ib Postgrad Med       Date:  2020-12

Review 9.  Editorial review: pediatric 3D ultrasound.

Authors:  Michael Riccabona
Journal:  J Ultrason       Date:  2014-03-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.