Literature DB >> 7835161

Scoring of radiation-induced micronuclei in cytokinesis-blocked human lymphocytes by automated image analysis.

F Verhaegen1, A Vral, J Seuntjens, N W Schipper, L de Ridder, H Thierens.   

Abstract

The micronucleus assay in human lymphocytes is, at present, frequently used to assess chromosomal damage caused by ionizing radiation or mutagens. Manual scoring of micronuclei (MN) by trained personnel is very time-consuming, tiring work, and the results depend on subjective interpretation of scoring criteria. More objective scoring can be accomplished only if the test can be automated. Furthermore, an automated system allows scoring of large numbers of cells, thereby increasing the statistical significance of the results. This is of special importance for screening programs for low doses of chromosome-damaging agents. In this paper, the first results of our effort to automate the micronucleus assay with an image-analysis system are represented. The method we used is described in detail, and the results are compared to those of other groups. Our system is able to detect 88% of the binucleated lymphocytes on the slides. The procedure consists of a fully automated localization of binucleated cells and counting of the MN within these cells, followed by a simple and fast manual operation in which the false positives are removed. Preliminary measurements for blood samples irradiated with a dose of 1 Gy X-rays indicate that the automated system can find 89% +/- 12% of the micronuclei within the binucleated cells compared to a manual screening.

Entities:  

Mesh:

Year:  1994        PMID: 7835161     DOI: 10.1002/cyto.990170203

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  6 in total

Review 1.  Laser scanning cytometry for automation of the micronucleus assay.

Authors:  Zbigniew Darzynkiewicz; Piotr Smolewski; Elena Holden; Ed Luther; Mel Henriksen; Maxime François; Wayne Leifert; Michael Fenech
Journal:  Mutagenesis       Date:  2011-01       Impact factor: 3.000

2.  Automated analysis of the cytokinesis-block micronucleus assay for radiation biodosimetry using imaging flow cytometry.

Authors:  M A Rodrigues; L A Beaton-Green; B C Kutzner; R C Wilkins
Journal:  Radiat Environ Biophys       Date:  2014-03-07       Impact factor: 1.925

3.  In vitro micronucleus assay scored by flow cytometry provides a comprehensive evaluation of cytogenetic damage and cytotoxicity.

Authors:  Steven M Bryce; Jeffrey C Bemis; Svetlana L Avlasevich; Stephen D Dertinger
Journal:  Mutat Res       Date:  2007-03-19       Impact factor: 2.433

4.  Radiation-induced micronucleus induction in lymphocytes identifies a high frequency of radiosensitive cases among breast cancer patients: a test for predisposition?

Authors:  D Scott; J B Barber; E L Levine; W Burrill; S A Roberts
Journal:  Br J Cancer       Date:  1998-02       Impact factor: 7.640

5.  Rapid and automatic detection of micronuclei in binucleated lymphocytes image.

Authors:  Xiang Shen; Ying Chen; Chaowen Li; Fucheng Yang; Zhanbo Wen; Jinlin Zheng; Zhenggan Zhou
Journal:  Sci Rep       Date:  2022-03-10       Impact factor: 4.379

6.  Inter-laboratory automation of the in vitro micronucleus assay using imaging flow cytometry and deep learning.

Authors:  George E Johnson; Paul Rees; John W Wills; Jatin R Verma; Benjamin J Rees; Danielle S G Harte; Qiellor Haxhiraj; Claire M Barnes; Rachel Barnes; Matthew A Rodrigues; Minh Doan; Andrew Filby; Rachel E Hewitt; Catherine A Thornton; James G Cronin; Julia D Kenny; Ruby Buckley; Anthony M Lynch; Anne E Carpenter; Huw D Summers
Journal:  Arch Toxicol       Date:  2021-07-10       Impact factor: 5.153

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.