Literature DB >> 7828253

Epidural opioid analgesia after caesarean section: a comparison of patient-controlled analgesia with meperidine and single bolus injection of morphine.

O P Rosaeg1, M P Lindsay.   

Abstract

The quality of analgesia, patient satisfaction and incidence of side effects following a single bolus of epidural morphine were compared with patient-controlled epidural analgesia (PCEA) with meperidine during the first 24 hr after elective Caesarean section. Seventy-five women were randomly assigned to three equal groups. Group I received 30 mg epidural meperidine after delivery and PCEA with meperidine; Group 2 received 3 mg epidural morphine after delivery and PCEA with saline in a double-blind fashion. Group 3 received 3 mg epidural morphine after delivery without saline PCEA. Visual analogue pain scores (VAS) were higher with PCEA meperidine from 8-16 hr post-operatively (P < 0.05) than in both epidural morphine groups. Two patients in Group 1 and one in Group 3 required supplemental parental analgesia. The incidence of nausea was 16% in Group 1, compared with 52% in Group 2 and 56% in Group 3 (P < 0.01). Pruritus occurred in 24% of Group 1 patients, 84% of patients in Group 2 and 68% of patients in Group 3 (P < 0.001). Forty-six percent of patients in Group 1 were very satisfied with pain management, compared with 77% in Group 2 and 79% in Group 3. Nurse workload was higher in the PCEA study groups than in Group 3 (P < 0.05). A single bolus of epidural morphine provides superior analgesia and satisfaction at low cost, but with a higher incidence of nausea and pruritus than PCEA with meperidine.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7828253     DOI: 10.1007/BF03015655

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  24 in total

1.  Epidural narcotic and patient-controlled analgesia for post-cesarean section pain relief.

Authors:  D M Harrison; R Sinatra; L Morgese; J H Chung
Journal:  Anesthesiology       Date:  1988-03       Impact factor: 7.892

2.  Mishaps with patient-controlled analgesia.

Authors:  P F White
Journal:  Anesthesiology       Date:  1987-01       Impact factor: 7.892

3.  Intrathecal and epidural morphine sulfate for post-cesarean analgesia--a clinical comparison.

Authors:  H S Chadwick; L B Ready
Journal:  Anesthesiology       Date:  1988-06       Impact factor: 7.892

4.  Latent dural puncture after lumbar epidural block.

Authors:  J A Robson; J B Brodsky
Journal:  Anesth Analg       Date:  1977 Sep-Oct       Impact factor: 5.108

5.  Epidural morphine for the relief of postoperative pain after cesarean delivery.

Authors:  M A Rosen; S C Hughes; S M Shnider; T K Abboud; M Norton; P A Dailey; J D Curtis
Journal:  Anesth Analg       Date:  1983-07       Impact factor: 5.108

6.  Epidural morphine for analgesia after caesarean section: a report of 4880 patients.

Authors:  J G Fuller; G H McMorland; M J Douglas; L Palmer
Journal:  Can J Anaesth       Date:  1990-09       Impact factor: 5.063

7.  Analgesia following extradural and i.m. pethidine in post-caesarean section patients.

Authors:  B W Perriss; B V Latham; I H Wilson
Journal:  Br J Anaesth       Date:  1990-03       Impact factor: 9.166

8.  Analgesia after cesarean delivery: patient evaluations and costs of five opioid techniques.

Authors:  S E Cohen; L L Subak; W G Brose; J Halpern
Journal:  Reg Anesth       Date:  1991 May-Jun

9.  Epidural patient-controlled analgesia after cesarean section: buprenorphine-0.015% bupivacaine with epinephrine versus fentanyl-0.015% bupivacaine with and without epinephrine.

Authors:  S Cohen; D Amar; C B Pantuck; E J Pantuck; A M Weissman; S Landa; N Singer
Journal:  Anesth Analg       Date:  1992-02       Impact factor: 5.108

10.  A study of pethidine kinetics and analgesia in women in labour following intravenous, intramuscular and epidural administration.

Authors:  R P Husemeyer; A J Cummings; J R Rosankiewicz; H T Davenport
Journal:  Br J Clin Pharmacol       Date:  1982-02       Impact factor: 4.335

View more
  2 in total

1.  Postoperative analgesic effect of epidural neostigmine following caesarean section.

Authors:  M Alkan; K Kaya
Journal:  Hippokratia       Date:  2014-01       Impact factor: 0.471

Review 2.  Cost considerations in patient-controlled analgesia.

Authors:  A Jacox; D B Carr; D M Mahrenholz; B M Ferrell
Journal:  Pharmacoeconomics       Date:  1997-08       Impact factor: 4.981

  2 in total