Literature DB >> 7824707

Thoracic aortic dissection: diagnosis with transesophageal echocardiography versus MR imaging.

J P Laissy1, F Blanc, P Soyer, P Assayag, A Sibert, D Tebboune, L Arrivé, E Brochet, U Hvass, J Langlois.   

Abstract

PURPOSE: To compare transesophageal echocardiography (TEE) and magnetic resonance (MR) imaging in the diagnosis of dissection of the thoracic aorta.
MATERIALS AND METHODS: Thirty-one consecutive patients with clinically suspected aortic dissection and 10 postoperative patients underwent transesophageal color Doppler echocardiography and MR imaging. Imaging results were compared at independent double-blind readings. Final diagnosis was obtained from consensual review of all corroborative studies.
RESULTS: MR imaging depicted the intimal flap in 95% of aortic dissections; TEE, in 86% (P < .05). In surgical patients, the sensitivity of MR in detection of residual dissection was 100% versus 86% with TEE (P < .05). The inferior extent of the dissected lumen was seen only with MR imaging. False-positive results occurred in two cases with TEE and in one with MR imaging.
CONCLUSION: MR imaging is superior to TEE in the evaluation and follow-up of dissection of the thoracic aorta. Because the availability of MR is limited, however, TEE should remain the standard modality for diagnosis.

Entities:  

Mesh:

Year:  1995        PMID: 7824707     DOI: 10.1148/radiology.194.2.7824707

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

Review 1.  Current concepts in the evaluation of vascular disease: magnetic resonance and computed tomographic angiography.

Authors:  B D Toombs; J M Jing
Journal:  Tex Heart Inst J       Date:  2000

2.  Segmented K-space cine breath-hold cardiovascular MR imaging: Part 1. Principles and technique.

Authors:  D A Bluemke; J L Boxerman; E Atalar; E R McVeigh
Journal:  AJR Am J Roentgenol       Date:  1997-08       Impact factor: 3.959

3.  Comparative evaluation of TEE, conventional MRI and contrast-enhanced 3D breath-hold MRA in the post-operative follow-up of dissecting aneurysms.

Authors:  E Di Cesare; A V Giordano; G Cerone; F De Remigis; G Deusanio; C Masciocchi
Journal:  Int J Card Imaging       Date:  2000-06

Review 4.  Screening, evaluation, and early management of acute aortic dissection in the ED.

Authors:  Reuben J Strayer; Peter L Shearer; Luke K Hermann
Journal:  Curr Cardiol Rev       Date:  2012-05

Review 5.  Computational medical imaging and hemodynamics framework for functional analysis and assessment of cardiovascular structures.

Authors:  Kelvin K L Wong; Defeng Wang; Jacky K L Ko; Jagannath Mazumdar; Thu-Thao Le; Dhanjoo Ghista
Journal:  Biomed Eng Online       Date:  2017-03-21       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.