Review article: radiation protection in dental radiology.

K Horner1.   

Abstract

Dental radiology represents the most frequent diagnostic radiological investigation in the industrialized world, with over 16 million examinations performed annually in England and Wales alone. Although individual doses and risks are low in dental radiography, the collective dose is not inconsiderable and many examinations are performed in younger age groups. Radiation protection of patients in dental radiology is achieved in three ways: by appropriate selection criteria for patients and equipment, methods of dose limitation and quality assurance procedures. There is a lack of agreed radiographic selection criteria to guide British dentists and this may lead to overuse of certain techniques, principally panoramic radiography. In intraoral radiography the use of fast (E-speed) film and rectangular collimation offer dose reductions of approximately 50% and 60%, respectively. Constant potential X-ray units and rare-earth filtration permit further reductions. In panoramic and cephalometric radiography, improved collimation offers a simple means of dose limitation, while doses can be reduced by up to one-eighth by combining the use of constant potential X-ray units, rare-earth intensifying screens and rare-earth filtration. Lead protection of the abdomen has little relevance to radiation protection; however, thyroid shielding has some value. Concern has been expressed about the poor diagnostic quality of radiographs taken in the general dental services. Consequently a quality assurance programme plays an essential part in dental radiation protection by improving diagnostic yield and limiting repeat examinations.

Entities:  

Mesh:

Year:  1994        PMID: 7820393     DOI: 10.1259/0007-1285-67-803-1041

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

1.  Compliance of Iranian dentists with safety standards of oral radiology.

Authors:  S Shahab; A Kavosi; H Nazarinia; S Mehralizadeh; M Mohammadpour; M Emami
Journal:  Dentomaxillofac Radiol       Date:  2012-02       Impact factor: 2.419

2.  Influence of lead apron shielding on absorbed doses from panoramic radiography.

Authors:  D Rottke; L Grossekettler; K Sawada; P Poxleitner; D Schulze
Journal:  Dentomaxillofac Radiol       Date:  2013-10-30       Impact factor: 2.419

3.  Skin entrance dose with and without lead apron in digital panoramic radiography for selected sensitive body regions.

Authors:  Ralf Kurt Willy Schulze; Catrin Cremers; Heiko Karle; Hugo de Las Heras Gala
Journal:  Clin Oral Investig       Date:  2016-06-21       Impact factor: 3.573

4.  Positioning errors and quality assessment in panoramic radiography.

Authors:  Manu Dhillon; Srinivasa M Raju; Sankalp Verma; Divya Tomar; Raviprakash S Mohan; Manisha Lakhanpal; Bhuvana Krishnamoorthy
Journal:  Imaging Sci Dent       Date:  2012-12-23

Review 5.  Common positioning errors in panoramic radiography: A review.

Authors:  Rafael Henrique Nunes Rondon; Yamba Carla Lara Pereira; Glauce Crivelaro do Nascimento
Journal:  Imaging Sci Dent       Date:  2014-03-19

6.  Evidence on radiation dose reduction using rectangular collimation: a systematic review.

Authors:  Avdeesh Shetty; Fabiana T Almeida; Seema Ganatra; Anthea Senior; Camila Pacheco-Pereira
Journal:  Int Dent J       Date:  2018-06-29       Impact factor: 2.607

7.  Anatomically shaped cranial collimation (ACC) for lateral cephalometric radiography: a technical report.

Authors:  R C Hoogeveen; P F van der Stelt; W E R Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2013-10-29       Impact factor: 2.419

8.  A Nanocomposite Shield Constructed for Protection Against the Harmful Effects of Dental X-Rays.

Authors:  Simel Ayyıldız; Elif Hilal Soylu; Jülide Özen; Semra İde; Kıvanç Kamburoğlu
Journal:  J Dent (Tehran)       Date:  2015-05

9.  Correlation between spatial resolution and ball distortion rate of panoramic radiography.

Authors:  Han-Gyeol Yeom; Jo-Eun Kim; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  BMC Med Imaging       Date:  2020-06-19       Impact factor: 1.930

10.  Repeat film analysis and its implications for quality assurance in dental radiology: An institutional case study.

Authors:  Shruthi Acharya; Keerthilatha M Pai; Shashidhar Acharya
Journal:  Contemp Clin Dent       Date:  2015 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.