Literature DB >> 7818961

Non-smoke spontaneous contrast in left atrium intensified by respiratory manoeuvres: a new transoesophageal echocardiographic observation.

G Van Camp1, B Cosyns, J L Vandenbossche.   

Abstract

OBJECTIVE: To elucidate why different types of contrast appear in the left atrium during transoesophageal echocardiographic contrast studies. This should lead to a more uniform definition of true patent foramen ovale.
BACKGROUND: The Valsalva manoeuvre and cough are routinely used to enhance right to left shunt for the detection of patent foramen ovale. No information is, however, available on the effect of these manoeuvres on the intrinsic echogenicity of blood in the left atrium.
METHODS: 30 consecutive patients referred for transoesophageal echocardiography were studied. Gain settings were relatively high so that no details were lost. The appearance of contrast during normal respiration, cough, and the Valsalva manoeuvre was looked for in the left atrium with and without venous injection of 10 ml of 5% dextrose. Frequency of contrast appearance in the left atrium was expressed as a percentage. Intensity of contrast, when present, was graded 1 (mild), 2 (moderate), or 3 (equal to right atrial contrast during injection). Timing was assessed in cardiac cycles after the end of respiratory manoeuvres.
RESULTS: Left atrial contrast appeared as a "snowstorm" flowing from the right pulmonary veins towards the middle of the left atrium. It was present respectively with and without contrast injection in eight and five patients during normal respiration, in 15 and seven during a cough, and in 20 and 14 during the Valsalva manoeuvre. When present, the mean intensity of contrast was 1.0 during normal respiration, 1.4 during a cough, and 1.4 during the Valsalva manoeuvre. The mean delay of contrast appearance was 3-4 cycles after release of the Valsalva manoeuvre and after onset of cough.
CONCLUSIONS: Respiratory manoeuvres frequently induce the transient appearance of mild to moderate contrast in the left atrium, most often independently of venous injections. Mild contrast was seen only with high gain settings. This contrast is likely to be related to transient stasis in the pulmonary circulation. In some cases peripheral venous injections of dextrose solution produced, without any respiratory manoeuvre, a similar contrast after the first four cardiac cycles of the right atrium filling, which is likely to represent recirculation of the injected bolus through the pulmonary capillary bed. Therefore respiratory manoeuvres should always be performed before contrast injections to allow better distinction between this background and true patent foramen ovale or pulmonary arteriovenous fistula.

Entities:  

Mesh:

Year:  1994        PMID: 7818961      PMCID: PMC1025612          DOI: 10.1136/hrt.72.5.446

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  21 in total

1.  Detection of patent foramen ovale by Doppler color flow mapping in patients undergoing cardiac catheterization.

Authors:  M E Brickner; P A Grayburn; B Fadel; M M Carry; E J Eichhorn; R A Lange; A L Taylor
Journal:  Am J Cardiol       Date:  1991-07-01       Impact factor: 2.778

2.  PFO or UFO? The role of a patent foramen ovale in cryptogenic stroke.

Authors:  R H Falk
Journal:  Am Heart J       Date:  1991-04       Impact factor: 4.749

3.  Prevalence of patent foramen ovale in patients with stroke.

Authors:  P Lechat; J L Mas; G Lascault; P Loron; M Theard; M Klimczac; G Drobinski; D Thomas; Y Grosgogeat
Journal:  N Engl J Med       Date:  1988-05-05       Impact factor: 91.245

4.  Intrapulmonary vascular dilatations (IPVD) in liver transplant candidates. Screening by two-dimensional contrast-enhanced echocardiography.

Authors:  M J Krowka; A J Tajik; E R Dickson; R H Wiesner; D A Cortese
Journal:  Chest       Date:  1990-05       Impact factor: 9.410

5.  Patent foramen ovale in young stroke patients.

Authors:  M W Webster; A M Chancellor; H J Smith; D L Swift; D N Sharpe; N M Bass; G L Glasgow
Journal:  Lancet       Date:  1988-07-02       Impact factor: 79.321

6.  Contrast echocardiographic visualization of cough-induced right to left shunt through a patent foramen ovale.

Authors:  O Dubourg; J P Bourdarias; J C Farcot; P Gueret; M Terdjman; A Ferrier; M Rigaud; J C Bardet
Journal:  J Am Coll Cardiol       Date:  1984-09       Impact factor: 24.094

7.  Why do the lungs clear ultrasonic contrast?

Authors:  R S Meltzer; E G Tickner; R L Popp
Journal:  Ultrasound Med Biol       Date:  1980       Impact factor: 2.998

8.  Pulmonary wedge injections yielding left-sided echocardiographic contrast.

Authors:  R S Meltzer; P W Serruys; J McGhie; N Verbaan; J Roelandt
Journal:  Br Heart J       Date:  1980-10

9.  Relation between patent foramen ovale and unexplained stroke.

Authors:  G Van Camp; D Schulze; B Cosyns; J L Vandenbossche
Journal:  Am J Cardiol       Date:  1993-03-01       Impact factor: 2.778

10.  Hemodynamic and hemorheologic determinants of left atrial spontaneous echo contrast and thrombus formation in patients with idiopathic dilated cardiomyopathy.

Authors:  P Siostrzonek; R Koppensteiner; H Gössinger; M Zangeneh; G Heinz; G Kreiner; A Stümpflen; P Buxbaum; H Ehringer; H Mösslacher
Journal:  Am Heart J       Date:  1993-02       Impact factor: 4.749

View more
  2 in total

1.  Transient right-sided Serratia endocarditis after a percutaneous transhepatic procedure.

Authors:  Daihiko Hakuno; Takumi Toya; Takeshi Adachi
Journal:  J Echocardiogr       Date:  2012-11-02

Review 2.  Point-of-care echocardiography for the evaluation of right-to-left cardiopulmonary shunts: a narrative review.

Authors:  Tim Montrief; Stephen Alerhand; André Denault; Jeffrey Scott
Journal:  Can J Anaesth       Date:  2020-09-17       Impact factor: 5.063

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.