Literature DB >> 7813824

Quantitative assessment of methods for the detection of otoacoustic emissions.

D Brass1, D T Kemp.   

Abstract

OBJECTIVE: To compare the performance of various types of signal detector commonly used to detect otoacoustic emissions (OAEs).
METHOD: The signal detectors were tested with signals in various types of noise, including noise with various amplitude distributions. Commonly utilized transient evoked OAE and distortion product OAE detectors were analyzed.
RESULTS: In both cases it was found that detector performance increased as the measurement bandwidth was increased. Noises of different amplitude distributions were found to affect the performance of both types of detectors. The effect of different amplitude distributions decreased as the measurement bandwidth was increased. For a given power per spectral line, the transient evoked OAE detector could detect signals 6 dB farther into gaussian noise than the distortion product OAE detector.
CONCLUSIONS: An analysis of the results of practical methods of OAE measurement show that distortion product OAEs can be measured with higher power per spectral line than transient evoked OAEs. This means that in adult humans distortion product OAEs can be reliably detected in about 1/14th of the time of transient evoked OAEs. In neonatal humans distortion product OAEs can be reliably detected in about two-thirds of the time of transient evoked OAEs.

Entities:  

Mesh:

Year:  1994        PMID: 7813824     DOI: 10.1097/00003446-199410000-00005

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  6 in total

Review 1.  Sudden sensorineural hearing loss: Is there a connection with inner ear electrolytic disorders? A literature review.

Authors:  Andrea Ciorba; Virginia Corazzi; Chiara Bianchini; Claudia Aimoni; Henryk Skarzynski; Piotr Henryk Skarzynski; Stavros Hatzopoulos
Journal:  Int J Immunopathol Pharmacol       Date:  2016-10-06       Impact factor: 3.219

Review 2.  Otoacoustic emissions.

Authors:  M Richardson
Journal:  Arch Dis Child       Date:  1995-10       Impact factor: 3.791

3.  Outcome of a newborn hearing screening program in a tertiary hospital in Malaysia: the first five years.

Authors:  Amirozi Ahmad; Irfan Mohamad; Suzana Mansor; Mohd Khairi Daud; Dinsuhaimi Sidek
Journal:  Ann Saudi Med       Date:  2011 Jan-Feb       Impact factor: 1.526

4.  Comparative multivariate analyses of transient otoacoustic emissions and distorsion products in normal and impaired hearing.

Authors:  Mirela Cristina Stamate; Nicolae Todor; Marcel Cosgarea
Journal:  Clujul Med       Date:  2015-11-15

5.  Contrasting Effects of Pressure Compensation on TEOAE and DPOAE in Children With Negative Middle Ear Pressure.

Authors:  Snezana A Filipović; Mark P Haggard; Helen Spencer; Goran Trajković
Journal:  Trends Hear       Date:  2018 Jan-Dec       Impact factor: 3.293

6.  Reduction of acoustic reflex threshold in neonates without auditory risk.

Authors:  Jordana Costa Soares; Renata M M Carvallo
Journal:  Braz J Otorhinolaryngol       Date:  2006 Jan-Feb
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.