Literature DB >> 7810493

Usefulness of a prototype intravascular ultrasound imaging in evaluation of aortic dissection and comparison with angiographic study, transesophageal echocardiography, computed tomography, and magnetic resonance imaging.

E Yamada1, M Matsumura, S Kyo, R Omoto.   

Abstract

The aim of this study was to evaluate the accuracy of information obtained with a prototype intravascular ultrasound (IVUS) system in chronic aortic dissection by comparing results with angiography, transesophageal echocardiography (TEE), computed tomography, or magnetic resonance imaging. We assigned 15 patients to IVUS imaging after they underwent angiography. The detection rate of the intimal flap was 100% in all segments of the aorta, and the detection rate of the intimal tear was 0%, 50%, 50%, and 77.8% in the ascending, arch, descending, and abdominal aorta, respectively. IVUS demonstrated 100% of the celiac and renal arteries, and 80% of the superior mesenteric arteries as well as their relation to dissection. It clarified the origin of 12 of 60 main abdominal branches (20%) which were not clear on the angiogram. It also determined the distal extent of the dissection in all cases. With regard to the size of the vessel, there was a good correlation between IVUS and computed tomographic values (r = 0.98, p < 0.01). No complications occurred in any patient. IVUS accurately demonstrated thrombus or spontaneous echo contrast in the false lumen that was confirmed with computed tomography or TEE, or both. It was especially useful in evaluating the abdominal aorta with regard to determining the size of the vessel, the extent of dissection, the relation of the branches to the false lumen, and the detection of intimal tears--important information for follow-up of patients and for planning surgery.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7810493     DOI: 10.1016/s0002-9149(00)80067-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  Potential interest of intra-aorta ultrasound imaging for the diagnosis of aortic penetrating atherosclerotic ulcer.

Authors:  Hu Wei; Francois Schiele; Nicolas Meneveau; Marie-France Seronde; Pierre Legalery; Jean-Francois Bonneville; Sidney Chocron; Jean-Pierre Bassand
Journal:  Int J Cardiovasc Imaging       Date:  2006-04-28       Impact factor: 2.357

Review 2.  [Acute aortic dissection. Differential diagnosis of a thoracic emergency].

Authors:  U Grundmann; H Lausberg; H-J Schäfers
Journal:  Anaesthesist       Date:  2006-01       Impact factor: 1.041

3.  Optical Microangiography: A Label Free 3D Imaging Technology to Visualize and Quantify Blood Circulations within Tissue Beds in vivo.

Authors:  Ruikang K Wang
Journal:  IEEE J Sel Top Quantum Electron       Date:  2010-05       Impact factor: 4.544

4.  The potential value of intravascular ultrasound imaging in diagnosis of aortic intramural hematoma.

Authors:  Wei Hu; Francois Schiele; Nicolas Meneveau; Marie-France Seronde; Pierre Legalery; Jean-Francois Bonneville; Sidney Chocron; Jean-Pierre Bassand
Journal:  J Geriatr Cardiol       Date:  2011-12       Impact factor: 3.327

5.  Noninvasive imaging analysis of biological tissue associated with laser thermal injury.

Authors:  Cheng-Jen Chang; De-Yi Yu; Yen-Chang Hsiao; Kuang-Hua Ho
Journal:  Biomed J       Date:  2017-05-04       Impact factor: 4.910

6.  High intimal flap mobility assessed by intravascular ultrasound is associated with better short-term results after TEVAR in chronic aortic dissection.

Authors:  Julia Lortz; Maria Papathanasiou; Christos Rammos; Martin Steinmetz; Alexander Lind; Konstantinos Tsagakis; Thomas Schlosser; Heinz Jakob; Tienush Rassaf; Rolf Alexander Jánosi
Journal:  Sci Rep       Date:  2019-05-13       Impact factor: 4.379

Review 7.  MRI in Chronic Aortic Dissection: A Systematic Review and Future Directions.

Authors:  Andrew G Sherrah; Stuart M Grieve; Richmond W Jeremy; Paul G Bannon; Michael P Vallely; Rajesh Puranik
Journal:  Front Cardiovasc Med       Date:  2015-02-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.