Literature DB >> 7809486

Simultaneous active compression-decompression and abdominal binding increase carotid blood flow additively during cardiopulmonary resuscitation (CPR) in pigs.

L Wik1, P A Naess, A Ilebekk, P A Steen.   

Abstract

The effects of adding active compression-decompression and abdominal binding separately or combined to standard compression CPR was tested in a randomized cross-over design during ventricular fibrillation in eight pigs. The flow and pressure effects of the two techniques appeared to be additive with no interference between the two. Carotid blood flow increased 22% with active compression-decompression, 34% with abdominal binding and 59% with the combination compared to flow with standard compression. Peak antegrade carotid flow occurred in early systole with retrograde flow in early diastole and close to zero in late diastole with no profound alterations induced by active decompression or abdominal binding. Abdominal binding increased the intrathoracic pressure during the compression phase as estimated from the esophageal pressure, while active decompression caused a negative esophageal pressure during the decompression phase. Neither active decompression nor abdominal binding caused any changes in the coronary perfusion pressure, nor in the left ventricular transmural pressure except for a rise in mid-diastolic pressure with active decompression.

Entities:  

Mesh:

Year:  1994        PMID: 7809486     DOI: 10.1016/0300-9572(94)90055-8

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  4 in total

1.  [Active compression-decompression resuscitation. Improved survival rate in an emergency medicine system with emergency physician assistance?].

Authors:  D Mauer; T Schneider; W Dick; D Elich; M Mauer
Journal:  Med Klin (Munich)       Date:  1997-07-15

2.  Cardiopulmonary resuscitation with active compression-decompression.

Authors:  C F Weston
Journal:  Br Heart J       Date:  1995-09

3.  Improved chest recoil using an adhesive glove device for active compression-decompression CPR in a pediatric manikin model.

Authors:  Jai P Udassi; Sharda Udassi; Melissa A Lamb; Kenneth E Lamb; Douglas W Theriaque; Jonathan J Shuster; Arno L Zaritsky; Ikram U Haque
Journal:  Resuscitation       Date:  2009-08-15       Impact factor: 5.262

4.  Haemodynamic outcomes during piston-based mechanical CPR with or without active decompression in a porcine model of cardiac arrest.

Authors:  Mikkel T Steinberg; Jan-Aage Olsen; Morten Eriksen; Andres Neset; Per Andreas Norseng; Jo Kramer-Johansen; Bjarne Madsen Hardig; Lars Wik
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2018-04-24       Impact factor: 2.953

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.