Literature DB >> 7808264

Radial turbo spin echo imaging.

V Rasche1, D Holz, W Schepper.   

Abstract

Fast MR imaging methods should provide a familiar contrast behavior at a reduced scan time. The multi-spin echo approach (TSE) is one of the most promising techniques satisfying this condition. Although the data acquisition time is significantly reduced, image quality may still suffer from artifacts due to patient motion and flow. The radial turbo spin echo (rTSE) approach combines TSE methods and projection reconstruction (PR) techniques. In PR images, artifacts induced by patient motion or flow are known to have a different appearance with lower level of intensity. The contrast and artifact behavior of the rTSE approach has been investigated. The new technique has been applied to abdominal imaging with acquisition times shorter than 30 s and to heart imaging in combination with cardiac triggering.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7808264     DOI: 10.1002/mrm.1910320512

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Hybrid T2 - and T1 -weighted radial acquisition for free-breathing abdominal examination.

Authors:  Thomas Benkert; John P Mugler; David S Rigie; Daniel K Sodickson; Hersh Chandarana; Kai Tobias Block
Journal:  Magn Reson Med       Date:  2018-04-15       Impact factor: 4.668

2.  Experimental O-space turbo spin echo imaging.

Authors:  Haifeng Wang; Leo Tam; Emre Kopanoglu; Dana C Peters; R Todd Constable; Gigi Galiana
Journal:  Magn Reson Med       Date:  2015-05-15       Impact factor: 4.668

3.  Multiecho acquisition of O-space data.

Authors:  Gigi Galiana; Dana Peters; Leo Tam; R Todd Constable
Journal:  Magn Reson Med       Date:  2014-01-23       Impact factor: 4.668

4.  Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI.

Authors:  Neville D Gai; Ashkan A Malayeri; David A Bluemke
Journal:  MAGMA       Date:  2017-03-10       Impact factor: 2.310

5.  Simultaneous auto-calibration and gradient delays estimation (SAGE) in non-Cartesian parallel MRI using low-rank constraints.

Authors:  Wenwen Jiang; Peder E Z Larson; Michael Lustig
Journal:  Magn Reson Med       Date:  2018-03-09       Impact factor: 4.668

6.  Hybrid radial-cones trajectory for accelerated MRI.

Authors:  Kevin M Johnson
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

7.  Free breathing 1H MRI of the human lung with an improved radial turbo spin-echo.

Authors:  Michael Völker; Philipp Ehses; Stefan Weick; Felix Arno Breuer; Martin Blaimer; Christian Hintze; Jürgen Biederer; Peter Michael Jakob
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

8.  Reducing contrast contamination in radial turbo-spin-echo acquisitions by combining a narrow-band KWIC filter with parallel imaging.

Authors:  Daniel Neumann; Felix A Breuer; Michael Völker; Tobias Brandt; Mark A Griswold; Peter M Jakob; Martin Blaimer
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

9.  Rapid water and lipid imaging with T2 mapping using a radial IDEAL-GRASE technique.

Authors:  Zhiqiang Li; Christian Graff; Arthur F Gmitro; Scott W Squire; Ali Bilgin; Eric K Outwater; Maria I Altbach
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

10.  Abdominal T2-Weighted Imaging and T2 Mapping Using a Variable Flip Angle Radial Turbo Spin-Echo Technique.

Authors:  Mahesh B Keerthivasan; Jean-Philippe Galons; Kevin Johnson; Lavanya Umapathy; Diego R Martin; Ali Bilgin; Maria I Altbach
Journal:  J Magn Reson Imaging       Date:  2021-07-13       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.