Literature DB >> 7806173

Noninvasive measurement of femoral blood flow and portal pressure response to propranolol in patients with cirrhosis.

A Luca1, J C García-Pagán, F Feu, J C Lopez-Talavera, M Fernández, C Bru, J Bosch, J Rodés.   

Abstract

This study investigated the correlation between changes in hepatic and systemic hemodynamics and femoral blood flow (FBF), measured by dual-beam pulsed wave Doppler, in 58 portal hypertensive patients receiving propranolol (0.15 mg/Kg intravenously; n = 44) or placebo (n = 14) under double-blind conditions. Placebo administration had no effects. Propranolol caused significant reductions (P < .0001) in hepatic venous pressure gradient (HVPG; from 19.1 +/- 4.1 to 16.2 +/- 4.2 mm Hg), azygos blood flow (from 563 +/- 204 to 387 +/- 176 mL/min), cardiac index (CI; from 4.4 +/- 1.0 to 3.3 +/- 0.8 L/m2/min), and FBF (from 237 +/- 79 to 176 +/- 58 mL/m2/min). In 17 patients HVPG decreased below 12 mm Hg and/or more than 20% of the baseline value (good response; mean change, -26 +/- 8%); in the remaining 27 patients (poor response) the mean change in HVPG was less: -9 +/- 6%. Patients with a good response had bled less often from varices, had significantly higher FBF (272 +/- 73 vs. 215 +/- 76 mL/m2/min) and lower baseline HVPG (16.8 +/- 3.9 vs. 20.6 +/- 3.6 mm Hg) than those with poor response in HVPG. The good response was also associated with greater decreases in FBF (-33 +/- 12 vs. -19 +/- 13% in poor responders), CI (-30 +/- 9 vs. -19 +/- 12%), and heart rate (-19 +/- 5 vs. -16 +/- 6%). A decrease in FBF of > 20% predicted a good response in 16 of 28 patients (positive predictive value, 57%).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7806173

Source DB:  PubMed          Journal:  Hepatology        ISSN: 0270-9139            Impact factor:   17.425


  4 in total

Review 1.  Diagnosis, prevention and treatment of hepatorenal syndrome in cirrhosis.

Authors:  Francesco Salerno; Alexander Gerbes; Pere Ginès; Florence Wong; Vicente Arroyo
Journal:  Gut       Date:  2007-03-27       Impact factor: 23.059

Review 2.  Duplex Doppler ultrasound examination of the portal venous system: an emerging novel technique for the estimation of portal vein pressure.

Authors:  Ashwani K Singal; Masood Ahmad; Roger D Soloway
Journal:  Dig Dis Sci       Date:  2009-07-23       Impact factor: 3.199

3.  Meta analysis of propranolol effects on gastrointestinal hemorrhage in cirrhotic patients.

Authors:  Jin-Wei Cheng; Liang Zhu; Ming-Jun Gu; Zhe-Ming Song
Journal:  World J Gastroenterol       Date:  2003-08       Impact factor: 5.742

4.  Impact of an acute hemodynamic response-guided protocol for primary prophylaxis of variceal bleeding.

Authors:  José Ignacio Fortea; Ángela Puente; Patricia Ruiz; Iranzu Ezcurra; Javier Vaquero; Antonio Cuadrado; María Teresa Arias-Loste; Joaquín Cabezas; Susana Llerena; Paula Iruzubieta; Carlos Rodríguez-Lope; Patricia Huelin; Fernando Casafont; Emilio Fábrega; Javier Crespo
Journal:  World J Clin Cases       Date:  2018-11-06       Impact factor: 1.337

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.