Literature DB >> 7802179

A comparison of 25 G and 27 G Whitacre needles for caesarean section.

E A Smith1, J Thorburn, R A Duckworth, J A Reid.   

Abstract

Spinal needles with a pencil-point tip and those of a finer gauge are known to be associated with a lower incidence of postdural puncture headache. This study set out to determine if fine pencil-point needles were acceptably easy to use in routine clinical practice. Two hundred and twelve women undergoing elective Caesarean section were randomly allocated to receive a subarachnoid block using either a 25 G or 27 G Whitacre needle. Factors determining ease of needle use, adequacy of block, incidence of postdural puncture headache, backache and neurological sequelae were assessed. Successful intrathecal injection was achieved in all patients in the 25 G group. Using the 27 G needle, the anaesthetist failed to reach the subarachnoid space in eight patients of which seven subsequently had a successful intrathecal injection with a larger needle. These failures were attributed to excessive needle flexibility which was the only significant difference in ease of use between the 25 G and 27 G needles. In the 25 G group, there was one severe postdural puncture headache which required an epidural blood patch and three mild headaches which resolved spontaneously. There were no postdural puncture headaches in the 27 G group. We conclude that the final choice of needle is a compromise between the ease of use and lower failure rate of the 25 G needle and the, as yet unproven, possibility of a lower incidence of postdural puncture headache with the 27 G needle.

Entities:  

Mesh:

Year:  1994        PMID: 7802179     DOI: 10.1111/j.1365-2044.1994.tb04258.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

Review 1.  Finer gauge of cutting but not pencil-point needles correlate with lower incidence of post-dural puncture headache: a meta-regression analysis.

Authors:  Andres Zorrilla-Vaca; Ryan Healy; Carolina Zorrilla-Vaca
Journal:  J Anesth       Date:  2016-07-28       Impact factor: 2.078

Review 2.  Needle gauge and tip designs for preventing post-dural puncture headache (PDPH).

Authors:  Ingrid Arevalo-Rodriguez; Luis Muñoz; Natalia Godoy-Casasbuenas; Agustín Ciapponi; Jimmy J Arevalo; Sabine Boogaard; Marta Roqué I Figuls
Journal:  Cochrane Database Syst Rev       Date:  2017-04-07

3.  Prospective randomized comparison of cerebrospinal fluid aspiration and conventional popping methods using 27-gauge spinal needles in patients undergoing spinal anaesthesia.

Authors:  J U Han; B G Kim; C Yang; W H Choi; J Jeong; K J Lee; H Kim
Journal:  BMC Anesthesiol       Date:  2020-01-30       Impact factor: 2.217

  3 in total