Left heart pacing and cardioembolic stroke.

M Sharifi1, R Sorkin, J B Lakier.   

Abstract

Three patients with inadvertently positioned left heart pacemaker leads were admitted for neurological symptoms consistent with embolic stroke. In one of them, the pacemaker lead crossed the interatrial septum, the mitral valve, and entered the left ventricle. In another it was erroneously placed through the subclavian artery, across the aortic valve, and into the left ventricular chamber. In the third patient, the right ventricular lead of a DDD pacemaker was placed in the coronary sinus and the right atrial lead crossed the interatrial septum, and intermittently entered the left ventricular cavity. Once anticoagulation was initiated, symptoms resolved; they recurred when the level of anticoagulation dropped leading to a major stroke in one of the patients. Two of the patients were on aspirin at the onset of symptoms. We believe that every approach must be considered to remove the malpositioned lead. Otherwise, full dose anticoagulation must be initiated since antiplatelet therapy alone does not confer adequate protection against stroke.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7800575     DOI: 10.1111/j.1540-8159.1994.tb02367.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

1.  Management of inadvertent left ventricular permanent pacing.

Authors:  Kostas E Paravolidakis; Eftihia S Hamodraka; Theofilos M Kolettis; Stavroula N Psychari; Thomas S Apostolou
Journal:  J Interv Card Electrophysiol       Date:  2004-06       Impact factor: 1.900

2.  Transient ischaemic attack due to the lead of an implantable defibrillator in the left heart.

Authors:  Anthony Alozie; Bernd Westphal; Can Yerebakan; Gustav Steinhoff
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-11-16

3.  Transvenous ICD lead malposition in the left ventricle: long-term follow-up.

Authors:  Harald Franck; Helmut Wollschläger
Journal:  Clin Res Cardiol       Date:  2012-08-07       Impact factor: 5.460

4.  Pacing lead inserted via the subclavian artery caused acute coronary syndrome.

Authors:  Peter Nordbeck; Heiner Langenfeld; Axel Krein; Wolfgang R Bauer; Oliver Ritter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

Review 5.  Endocardial transvenous pacing in patients with surgically palliated univentricular hearts: A review on different techniques, problems and management.

Authors:  Koneru Lakshmi Umamaheshwar; Arvind Sahadev Singh; Kothandam Sivakumar
Journal:  Indian Pacing Electrophysiol J       Date:  2018-11-30

6.  Inadvertent lead placement in the left ventricle: a case report and brief review.

Authors:  David D McManus; Mary-Lee Mattei; Karen Rose; Jason Rashkin; Lawrence S Rosenthal
Journal:  Indian Pacing Electrophysiol J       Date:  2009-07-01

7.  An unusual cause of transient ischemic attack in a patient with pacemaker.

Authors:  Jagadeesh Kumar Kalavakunta; Vishal Gupta; Basil Paulus; William Lapenna
Journal:  Case Rep Cardiol       Date:  2014-02-04

8.  Inadvertent defibrillator lead placement into the left ventricle after MitraClip implantation: A case report.

Authors:  Giuseppe Santarpia; Francesco Passafaro; Eugenia Pasceri; Annalisa Mongiardo; Antonio Curcio; Ciro Indolfi
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.