Literature DB >> 7798287

A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis.

D Bluestein1, S Einav, N H Hwang.   

Abstract

In vivo cavitation in cardiovascular flow fields may occur under very unusual circumstances as a localized transient phenomenon which are confined to very small regions in the vicinity of the valve body or leaflet surface. The violent collapse of cavitation bubbles induces local erosion that may lead to structural damage. The fluid mechanical factors that may cause in vivo cavitation inception in mechanical heart valve (MHV) prostheses are investigated. It is established that the closing velocity of the leaflet holds the key to MHV cavitation. During the final phase of valve closing, the fluid mass in the gap space between the closing occluder and the valve's body is squeezed into motion by the rapidly approaching boundaries. The flow pattern created by this motion (termed 'squeeze flow'), is found to be related to the valve geometry, and the impact velocity of the closing leaflet. Given the closing velocity of the leaflet and the geometry of the MHV, computational flow dynamics (CFD) are made to determine the velocity distributions in the gap flow field of a bileaflet MHV in the mitral position. A two dimensional, time dependent model of the gap space show that flow velocity in the gap space can reach values as high as 30 ms-1 in regions near the edge of the inflow surface of the Edwards Duromedics (ED) MHV leaflet. This high speed stream ejected from the gap channel can create the conditions that characterize cavitation. The location of the isolated high speed region corresponds to the surface erosion that was observed in a number of damaged ED-MHV explants.

Entities:  

Mesh:

Year:  1994        PMID: 7798287     DOI: 10.1016/0021-9290(94)90046-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Three-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics.

Authors:  Rui Cheng; Yong G Lai; Krishnan B Chandran
Journal:  Ann Biomed Eng       Date:  2004-11       Impact factor: 3.934

2.  Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart.

Authors:  Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

3.  Dynamics of a mechanical monoleaflet heart valve prosthesis in the closing phase: effect of squeeze film.

Authors:  C Gill-Jeong; K B Chandran
Journal:  Ann Biomed Eng       Date:  1995 Mar-Apr       Impact factor: 3.934

Review 4.  Simulation of Mechanical Heart Valve Dysfunction and the Non-Newtonian Blood Model Approach.

Authors:  Aolin Chen; Adi Azriff Bin Basri; Norzian Bin Ismail; Masaaki Tamagawa; Di Zhu; Kamarul Arifin Ahmad
Journal:  Appl Bionics Biomech       Date:  2022-04-19       Impact factor: 1.664

5.  Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.

Authors:  Danny Bluestein; Gaurav Girdhar; Shmuel Einav; Marvin J Slepian
Journal:  J Biomech       Date:  2012-12-06       Impact factor: 2.712

6.  Can vortices in the flow across mechanical heart valves contribute to cavitation?

Authors:  I Avrahami; M Rosenfeld; S Einav; M Eichler; H Reul
Journal:  Med Biol Eng Comput       Date:  2000-01       Impact factor: 3.079

7.  Adverse Hemodynamic Conditions Associated with Mechanical Heart Valve Leaflet Immobility.

Authors:  Fardin Khalili; Peshala P T Gamage; Richard H Sandler; Hansen A Mansy
Journal:  Bioengineering (Basel)       Date:  2018-09-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.