Literature DB >> 7798107

Joint motion of bipolar femoral prostheses.

H Izumi1, T Torisu, I Itonaga, S Masumi.   

Abstract

From 1982 to 1992, 251 bipolar hip arthroplasties were performed on 213 patients. Among them, 117 bipolar femoral prostheses were randomly selected to examine the behavior of abduction motion under weight-bearing loads. Roentgenographic motion study was performed at an average of 46.5 months after surgery (range, 2-110 months). One hundred one prostheses used in dysplastic osteoarthritic, rheumatoid, and revised failed total hip arthroplasty patients moved 18.2% at the outer bearing and 81.8% at the inner bearing, while 16 prostheses used in femoral neck fracture and osteonecrosis of the femoral head patients moved 49.7% at the inner bearing and 50.3% at the outer bearing. There was a statistical difference in the motion pattern between the two groups. The abduction motion behavior of the bipolar femoral prostheses was not affected by the length of the follow-up period, the diameter of the outer heads, or the position of the prostheses on immediate postoperative roentgenograms.

Entities:  

Mesh:

Year:  1995        PMID: 7798107     DOI: 10.1016/s0883-5403(05)80133-0

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

Review 1.  Patients with femoral neck fractures treated by bipolar hemiarthroplasty have superior to unipolar hip function and lower erosion rates and pain: a systematic review and meta-analysis of randomized controlled studies.

Authors:  Kyriakos Papavasiliou; Nifon K Gkekas; Dimitrios Stamiris; Ioannis Pantekidis; Eleftherios Tsiridis
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-07-02

2.  Radiographic evaluation of linear wear of bipolar hemiarthroplasty devices in vivo.

Authors:  Nobuhiro Kaku; Shouhei Noda; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2018-07-20

3.  Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults.

Authors:  Baldev Dudani; Ashok K Shyam; Pankush Arora; Arjun Veigus
Journal:  Indian J Orthop       Date:  2015 May-Jun       Impact factor: 1.251

4.  Cut-off values of latent infection in patients with rapid migration following bipolar hip hemiarthroplasty.

Authors:  Takao Setoguchi; Hirotaka Kawakami; Yasuhiro Ishidou; Hideki Kawamura; Junichiro Nishi; Takako Yoshioka; Hironori Kakoi; Satoshi Nagano; Masahiro Yokouchi; Akihide Tanimoto; Setsuro Komiya
Journal:  BMC Musculoskelet Disord       Date:  2016-01-19       Impact factor: 2.362

5.  Joint motion of bipolar hemiarthroplasty in routine hip functional movements: a dynamic motion study.

Authors:  Weizhou Jiang; Jun Xiao; Bin Chen; Ming Jia; Yang Zhang; Jian Wang; Zhanjun Shi
Journal:  BMC Musculoskelet Disord       Date:  2020-11-10       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.