Literature DB >> 7796693

Image processing algorithms for the automated micronucleus assay in binucleated human lymphocytes.

W Böcker1, W U Müller, C Streffer.   

Abstract

The frequency of micronuclei in binucleated lymphocytes (cytochalasin B assay) may serve as a biological dosimeter after radiation exposure. The automation of the micronucleus assay in binucleated human lymphocytes has been considerably advanced in recent years. In our studies for this purpose the detection of binucleated cells (BNCs) and the scoring of micronuclei (MN) was divided into two parts. First, detection of BNCs was feasible with low microscopic magnification (x 100). The positions of classified BNCs were stored. Second, after an automatic change of microscope objective, the stored BNCs were automatically analyzed in sequence at high microscopic magnification (x 630) for occurrence of MN. For both phases of image analysis we used empirical methods based on mathematical morphology. The system is able to recognize nearly 65% of BNCs with false positive decisions of 6% and about 75% of the MN with false positive decisions of 7%.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7796693     DOI: 10.1002/cyto.990190402

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  5 in total

1.  Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system.

Authors:  Oleksandra V Lyulko; Guy Garty; Gerhard Randers-Pehrson; Helen C Turner; Barbara Szolc; David J Brenner
Journal:  Radiat Res       Date:  2014-02-06       Impact factor: 2.841

2.  In vitro micronucleus assay scored by flow cytometry provides a comprehensive evaluation of cytogenetic damage and cytotoxicity.

Authors:  Steven M Bryce; Jeffrey C Bemis; Svetlana L Avlasevich; Stephen D Dertinger
Journal:  Mutat Res       Date:  2007-03-19       Impact factor: 2.433

3.  Radiation-induced micronucleus induction in lymphocytes identifies a high frequency of radiosensitive cases among breast cancer patients: a test for predisposition?

Authors:  D Scott; J B Barber; E L Levine; W Burrill; S A Roberts
Journal:  Br J Cancer       Date:  1998-02       Impact factor: 7.640

4.  Application of cell sorting for enhancing the performance of the cytokinesis-block micronucleus assay.

Authors:  Ayumi Nakamura; Satoru Monzen; Yuki Takasugi; Andrzej Wojcik; Yasushi Mariya
Journal:  J Radiat Res       Date:  2016-01-28       Impact factor: 2.724

5.  Rapid and automatic detection of micronuclei in binucleated lymphocytes image.

Authors:  Xiang Shen; Ying Chen; Chaowen Li; Fucheng Yang; Zhanbo Wen; Jinlin Zheng; Zhenggan Zhou
Journal:  Sci Rep       Date:  2022-03-10       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.