| Literature DB >> 7795821 |
I Gremeau1, V Sautou, V Pinon, F Rivault, J Chopineau.
Abstract
A rapid, accurate and selective method for the determination of isosorbide dinitrate and its 2- and 5-isosorbide mononitrate metabolites in 1.0 ml of human plasma has been developed. Before chromatographic quantitation by gas-liquid chromatography with electron-capture detection, the compounds are subjected to solid-phase extraction, using ENVI 18 cartridges (Supelco). The intra-day and inter-day coefficients of variation are less than 10%, except the inter-day coefficient of variation for the assay of 5-isosorbide dinitrate which is less than 15%. Limits of quantitation are 10, 10 and 20 ng/ml for isosorbide dinitrate, 2-isosorbide mononitrate and 5-isosorbide mononitrate, respectively. Recoveries are in excess of 90% for isosorbide dinitrate and 70% for its two metabolites.Entities:
Mesh:
Substances:
Year: 1995 PMID: 7795821 DOI: 10.1016/0378-4347(94)00543-e
Source DB: PubMed Journal: J Chromatogr B Biomed Appl ISSN: 1572-6495